Product Recognition | |
|---|
Certification Number | ZC14-25030506 |
|---|
Name | Power Strip |
|---|
Short Description | 5 Z-Wave controllable outlets in a single device with 2 USB ports and energy monitoring. |
|---|
Long Description | PRODUCT HIGHLIGHTS:
- Z-Wave® on/off control of up to 5 electrical devices
- On/off (charging/charged) reports from USB ports to the hub (no Z-Wave® control) - turn off the charging device for best results
- Energy monitoring for each of the 5 outlets
- NEW: 800 series Z-Wave® chip for better range and faster control
- Z-Wave® Long Range for ultra reliable no-mesh communication
- Built-in overload protection and ETL certification
- S2 Security and SmartStart for quicker and more secure set-up
SPECS:
- Model Number: ZEN20 800LR
- Z-Wave® Region: US / CA / MX
- Power: 120 VAC
- Maximum Load: 15 A total (between 5 outlets)
- Maximum Load for USB ports: 2.1 A total (between 2 ports)
- Cord Length: 2 feet
- Range: Up to 150 feet line of sight (or up to 1300 |
|---|
Brand | Zooz |
|---|
Product Identifier | ZEN20 800LR |
|---|
Product Line | Line A |
|---|
OEM Version | HW: 04 FW: 04.10 |
|---|
Hardware Platform | EFR32ZG23A |
|---|
Z-Wave Version | 7.19.3 |
|---|
Library Type | END_NODE_ENHANCED_232 |
|---|
Device Type | Binary Switch DT |
|---|
Role Type | ROLE_TYPE_END_NODE_ALWAYS_ON |
|---|
Manufacturer ID | 0x027A |
|---|
Product Type ID | 0xA000 |
|---|
Product ID | 0xA004 |
|---|
User Icon | 0x0800 |
|---|
Installer Icon | 0x0800 |
|---|
Frequency Plans | US: 916.00MHz, 908.40MHz, US_LR: 912.00MHz, 920.00MHz |
|---|
Categories | All Lighting Devices, On/Off Switches/Devices, Lighting Accessories |
|---|
Countries / Regions | Canada, Mexico, United States of America |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_BASIC_V2 | Basic V2 | 0x20 | 2 | COMMAND_CLASS_SWITCH_BINARY_V2 | Binary Switch V2 | 0x25 | 2 | COMMAND_CLASS_CONFIGURATION_V4 | Configuration V4 | 0x70 | 4 | COMMAND_CLASS_METER_V5 | Meter V5 | 0x32 | 5 | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information (AGI) V3 | 0x59 | 3 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta Data V5 | 0x7A | 5 | COMMAND_CLASS_INDICATOR_V3 | Indicator V3 | 0x87 | 3 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_MULTI_CHANNEL_V4 | Multi Channel V4 | 0x60 | 4 | COMMAND_CLASS_SECURITY_2 | Security 2 | 0x9F | 1 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 |
|
|---|
S2 Classes | S2_AUTHENTICATED, S2_UNAUTHENTICATED |
|---|
Documents | Category | File |
|---|
Manual_English | |
|
|---|
Features | Feature | Values |
|---|
Color | | Firmware Updatable | Value |
|---|
Updatable by Consumer by RF |
| Electric Load Type | | Loads Controlled | |
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Group Name | Profile |
|---|
1 | 5 | 0 | Lifeline | 0x0001 | 1 | 0 | 1 | Lifeline | 0x0001 | 1 | 0 | 2 | Lifeline | 0x0001 | 1 | 0 | 3 | Lifeline | 0x0001 | 1 | 0 | 4 | Lifeline | 0x0001 | 1 | 0 | 5 | Lifeline | 0x0001 | 1 | 0 | 6 | Lifeline | 0x0001 | 1 | 0 | 7 | Lifeline | 0x0001 |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value |
|---|
1 | Status recover | On/Off status recovery after power failure. | 1 | 1 | 0 | 0 | 0x00 | 2 | Wattage report threshold | Power wattage report value threshold. | 1 | 4 | 0 | 0 | 0x00000005 | 3 | Wattage report interval | Seconds for wattage report frequency. | 1 | 4 | 0 | 0 | 0x000000B4 | 4 | Energy report interval | Seconds for energy report frequency. | 1 | 4 | 0 | 0 | 0x0000012C | 5 | Overload protection threshold | Watt value for overload protection. | 1 | 2 | 0 | 0 | 0x05DC | 6 | EP1 auto turn off time enable | Enable or disable EP1 auto turn off timer. | 1 | 1 | 0 | 0 | 0x00 | 7 | EP1 auto turn off minutes | Minutes of EP1 turn off timer. | 1 | 4 | 0 | 0 | 0x0000003C | 8 | EP1 auto turn on time enable | Enable or disable EP1 auto turn on timer. | 1 | 1 | 0 | 0 | 0x00 | 9 | EP1 auto turn on minutes | Minutes of EP1 turn on timer. | 1 | 4 | 0 | 0 | 0x0000003C | 10 | EP2 auto turn off time enable | Enable or disable EP2 auto turn off timer. | 1 | 1 | 0 | 0 | 0x00 | 11 | EP2 auto turn off minutes | Minutes of EP2 turn off timer. | 1 | 4 | 0 | 0 | 0x0000003C | 17 | EP3 auto turn on minutes | Minutes of EP3 turn on timer. | 1 | 4 | 0 | 0 | 0x0000003C | 23 | EP5 auto turn off minutes | Minutes of EP5 turn off timer. | 1 | 4 | 0 | 0 | 0x0000003C | 24 | EP5 auto turn on time enable | Enable or disable EP5 auto turn on timer. | 1 | 1 | 0 | 0 | 0x00 | 25 | EP5 auto turn on minutes | Minutes of EP5 turn on timer. | 1 | 4 | 0 | 0 | 0x0000003C | 31 | EP3 Wattage and Energy report | Enable or disable EP3 wattage and energy report. | 1 | 1 | 0 | 0 | 0x01 |
|
|---|
Texts | ID | Description | Value |
|---|
8 | Where to find S2 DSK on product | Scan the QR code on the back of the device if your hub supports SmartStart inclusion. | 1 | Classic Inclusion | 1. Initiate inclusion (pairing) in the app (or web interface).
2. TAP THE CH1 BUTTON 3 TIMES QUICKLY if using traditional Z-Wave inclusion.
3. The LED indicators will blink blue to signal communication. | 2 | Classic Exclusion | 1. Bring your Z-Wave gateway (hub) close to the switch if possible
2. Put the Z-Wave hub into exclusion mode (not sure how to do that? ask@getzooz.com)
3. Tap the CH1 button 3 times quickly (the LED indicator will start blinking blue)
4. Your hub will confirm exclusion and all of the channels (child outlets) and the main device will disappear from your controller's device list. | 5 | Factory Reset Procedure | If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To complete the reset process manually, click-click-click’n’hold CH1 button for at least 10 seconds. All LED indicators will flash to confirm successful reset.
NOTE: All previously recorded activity and custom settings EXCEPT for the kWh record will be erased from the device’s memory. |
|
|---|
Supported / Controlled Meter Types | Meter Type | Rate Type |
|---|
Electric meter | Import (consumed) |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Power Management | Over-current status: Over-current detected |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Supports SmartStart | Yes |
|---|