| 6 | Basic Set Attempts | Make multiple attempts for all Basic Set Commands. Number of extra attempts sent every minute after first send. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | Disabled | | 1 | 5 | Number of extra attempts, unsigned |
|
| 7 | Temp Units | Temperature Units | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 0 | 0 | Celsius | | 1 | 1 | Fahrenheit |
|
| 8 | Group1 Temp Threshold | Group1 - temperature delta auto-send threshold (how many degrees changed from the last auto-send) | 0 | 1 | 0 | 0 | 10 | | From | To | Description |
|---|
| 1 | 200 | Tenths of degrees, unsigned |
|
| 9 | Group1 Temp Interval | Group1 - periodic temperature send interval (minutes) | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 1 | 120 | Minutes, unsigned | | 0 | 0 | Disabled |
|
| 10 | Group2 Temp Threshold | Group2 - temperature delta auto-send threshold (how many degrees change from the last auto-send) | 0 | 1 | 0 | 0 | 10 | | From | To | Description |
|---|
| 1 | 50 | Tenths of degrees, unsigned |
|
| 11 | Group2 Temp Interval | Group2 - periodic temperature send interval (minutes) | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | Disabled | | 1 | 120 | Minutes, unsigned |
|
| 17 | Group1 RH Interval | Group1 - periodic humidity send interval (minutes) | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | Disabled | | 1 | 120 | Minutes, unsigned |
|
| 1 | Battery Report Interval | Time between Battery Reports in hours | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | Disabled | | 1 | 127 | Hours, unsigned |
|
| 2 | Basic Set ON Above Temp | Send Basic Set ON above temp | 0 | 1 | 0 | 0 | 121 | | From | To | Description |
|---|
| 121 | 121 | Disabled | | -40 | 120 | Fahrenheit |
|
| 3 | Basic Set ON Below Temp | Send Basic Set ON below temp | 0 | 1 | 0 | 0 | 121 | | From | To | Description |
|---|
| -40 | 120 | Fahrenheit | | 121 | 121 | Disabled |
|
| 5 | Basic Set OFF Below Temp | Send Basic Set OFF below temp | 0 | 1 | 0 | 0 | 121 | | From | To | Description |
|---|
| -40 | 120 | Fahrenheit | | 121 | 121 | Disabled |
|
| 4 | Basic Set OFF Above Temp | Send Basic Set OFF above temp | 0 | 1 | 0 | 0 | 121 | | From | To | Description |
|---|
| 121 | 121 | Disabled | | -40 | 120 | Fahrenheit |
|