Product Recognition | |
|---|
Certification Number | ZC10-19116787 |
|---|
Name | Ring Retrofit Alarm Kit |
|---|
Short Description | Ring Retrofit Alarm Kit is a Wired-to-wireless bridge that connects to your existing hardwired contact sensors and transmits open/close events wirelessly to Ring Alarm. |
|---|
Long Description | Ring Retrofit Alarm Kit is a Wired-to-wireless bridge that connects to your existing hardwired contact sensors and transmits open/close events wirelessly to Ring Alarm. Connect up to 8 wired contact sensor zones to the device. Set up and configure the device using the Ring app. After installation and setup, monitor and receive notifications when doors and windows with wired sensors connected to Retrofit Alarm Kit open and close. The Ring Alarm Base Station is required to enable Retrofit Alarm Kit features and functions. Once setup, wired sensors connected to Retrofit Alarm Kit can be monitored just like other Ring Alarm sensors in the system. |
|---|
Brand | Ring |
|---|
Product Identifier | 4AW1SZ-0EN0 |
|---|
Product Line | Ring Security |
|---|
OEM Version | HW: 1 FW: 1.00:01.00 |
|---|
Hardware Platform | ZM5101 |
|---|
Z-Wave Version | 6.81.03 |
|---|
Library Type | SLAVE_ENHANCED_232 |
|---|
Device Type | Notification Sensor |
|---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_REPORTING |
|---|
Manufacturer ID | 0x0346 |
|---|
Product Type ID | 0x0B01 |
|---|
Product ID | 0x0101 |
|---|
User Icon | 0x0C07 |
|---|
Installer Icon | 0x0C07 |
|---|
Frequency Plans | US: 916.00MHz, 908.40MHz |
|---|
Categories | Sensors |
|---|
Countries / Regions | United States of America |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 | Firmware Update Meta-Data V4 | 0x7A | 4 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi-Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | COMMAND_CLASS_MULTI_CHANNEL_V4 | Multi-Channel V4 | 0x60 | 4 | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | COMMAND_CLASS_BASIC_V2 | Basic V2 | 0x20 | 2 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 |
|
|---|
S2 Classes | S2_UNAUTHENTICATED, S2_AUTHENTICATED |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product Manual | | Manual_English | Product Manual in English | |
|
|---|
Features | Feature | Values |
|---|
Battery Type | | Color | |
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Group Name | Description |
|---|
1 | 1 | 0 | Lifeline | Group one is a lifeline group who will receive unsolicited messages relating to case tamper notifications, battery level notifications, Wake-Up notifications, and Device Reset Notifications. | 2 | 1 | 0 | Multi-channel association | Group two is intended to be used with multi-channel association for a controller to subscribe to contact switch open/close notifications sent encapsulated from each of the eight endpoints one for each contact switch. Each endpoint must be enabled by putting the controller’s node ID into the device’s Association Group 2 with either an Association Set encapsulated with Multi-Channel Encapsulation OR a Multi-Channel Association Set encapsulated with Multi-Channel Encapsulation. |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
1 | Heartbeats | Number of seconds between periodic battery reports. (Heartbeats) | 1 | 2 | 255 | 4200 | 4200 | From | To | Description |
|---|
255 | 4200 | Number of seconds between periodic battery reports. (Heartbeats) |
| 2 | One-Time Wakeup Notification | One-Time Wakeup Notification. (In addition to normal Wakeup Notification) | 1 | 2 | 1 | 3600 | 0 | From | To | Description |
|---|
1 | 3600 | One-Time Wakeup Notification. (In addition to normal Wakeup Notification) |
| 4 | seconds to sleep | The minimum number of seconds to sleep between application level retries. | 1 | 1 | 1 | 60 | 6 | From | To | Description |
|---|
1 | 60 | The minimum number of seconds to sleep between application level retries. |
| 5 | Application Retry Multiplier | Application Retry Multiplier. The number of seconds between a current application retry is the count of retries multiplied by this number in seconds + a small random delay. | 1 | 1 | 1 | 5 | 1 | From | To | Description |
|---|
1 | 5 | Application Retry Multiplier. The number of seconds between a current application retry is the count of retries multiplied by this number in seconds + a small random delay. |
| 6 | wait for a Supervisory Report | The number of milliseconds to wait for a Supervisory Report in response to a Supervisory encapsulated Get. | 1 | 2 | 500 | 5000 | 1500 | From | To | Description |
|---|
500 | 5000 | The number of milliseconds to wait for a Supervisory Report in response to a Supervisory encapsulated Get. |
|
|
|---|
Texts | ID | Description | Value |
|---|
2 | Classic Exclusion | Exclusion Instructions:
1. Initiate remove keypad flow in the Ring Alarm mobile application – Select the settings icon from device details page and choose “Remove Device”
2. Press and hold “1” key for three seconds
3. When the exclusion process is complete, the LED on the keypad will be solid blue, then go out
4. Test the Keypad. Any button presses would not beep | 8 | Where to find S2 DSK on product | When prompted for the QR Code or DSK PIN, you can find them inside of the top cover of the device, on the box, or on a card inside the box. Keep the device nearby. You’ll be prompted to pull the battery tab to confirm the connection. | 1 | Classic Inclusion | Classic Inclusion Steps:
1. Initiate add flow in the Ring Alarm mobile application – Follow the guided add flow instructions provided in the Ring Alarm Mobile application
2. Select add manually and enter the 5 digit DSK pin found on the package of the Ring Alarm Retrofit Kit or the 5 digit DSK pin found on the inside of the top cover of the device.
4. When the inclusion process in complete, the LED on the keypad will be solid green, then go out.
Smart Start Inclusion Steps:
1. Initiate add flow in the Ring Alarm mobile application – Follow the guided add flow instructions provided in the Ring Alarm Mobile application
2. Scan the QR code found on the package of the Ring Alarm Retrofit Kit or the QR code found on the inside of the top cover of the device.
4. When the inclusion process in complete, the LED on the keypad will be solid green, then go out. | 4 | Wake-Up Procedure | The sensor will wake up every so often to send a Wake-Up Notification to allow the life line master node controller that the sensor is now available for any queued messages that the controller may have for the sensor. The time between Wake-Up Notifications can be configured with the Wake-Up Notification command class to be between 1 and 24 hours with interval steps of 1 minute. | 5 | Factory Reset Procedure | Ring Keypad – Reset
Factory Default Instructions
1. Press and hold “5” key and using a pointed end of a paperclip, gently press and release reset button via the reset pinhole found at the back of the keypad
2. Red network LED at the top left-hand corner will start to blink rapidly
3. Wait for the red LED to stop blinking then release the “5” key
Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Home Security | Sensor status: Intrusion | Home Security | Cover status: Tampering, product cover removed | Home Security | Tampering, product moved |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|