25 | Outputs orientation | This parameter allows reversing the operation of Q1 and Q2 without changing the wiring (in case of invalid motor connection) to ensure proper operation. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | default (Q1 - 1st channel, Q2 - 2nd channel) | 1 | 1 | reversed (Q1 - 2nd channel, Q2 - 1st channel) |
|
31 | Alarm configuration - 2nd slot (Water) | This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set according to the official Z-Wave protocol specification. | 0 | 4 | 0 | 0 | 0 | From | To | Description |
|---|
1 | 1 | Notification Type | 2 | 2 | Notification Status | 3 | 3 | Event/State Parameters | 4 | 4 | action: 0- no action, 1-open blinds, 2-close blinds |
|
24 | Inputs orientation | This parameter allows reversing the operation of switches connected to S1 and S2 without changing the wiring. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
1 | 1 | reversed (S1 - 2nd channel, S2 - 1st channel) | 0 | 0 | default (S1 - 1st channel, S2 - 2nd channel) |
|
41 | S2 switch - scenes sent | This parameter determines which actions result in sending scene IDs assigned to them. NOTE: Parameter 41 values may be combined, e.g. 1+2=3 means that scenes for single and double click are sent. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
2 | 2 | Key pressed 2 times | 4 | 4 | Key pressed 3 times | 1 | 1 | Key pressed 1 time | 8 | 8 | Key hold down and key released |
|
60 | Measuring power consumed by the device itself | This parameter determines whether the power metering should include the amount of active power consumed by the device itself. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
1 | 1 | function active | 0 | 0 | function inactive |
|
65 | Energy reports - on change | This parameter determines the minimum change in consumed energy that will result in sending new energy report to the main controller. | 0 | 2 | 0 | 0 | 10 | From | To | Description |
|---|
0 | 0 | reports are disabled | 1 | 500 | change in energy |
|
150 | Force calibration | By setting this parameter to 2 the device enters the calibration mode. The parameter relevant only if the device is set to work in positioning mode (parameter 151 set to 1, 2 or 4). | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | device is not calibrated | 1 | 1 | device is calibrated | 2 | 2 | force device calibration |
|
151 | Operating mode | This parameter allows adjusting operation according to the connected device. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
1 | 1 | roller blind (with positioning) | 4 | 4 | gate (with positioning) | 3 | 3 | gate (without positioning) | 6 | 6 | roller blind with built-in driver (impulse) | 5 | 5 | roller blind with built-in driver | 2 | 2 | Venetian blind (with positioning) |
|
152 | Venetian blind - time of full turn of the slats | For Venetian blinds (parameter 151 set to 2) the parameter determines time of full turn cycle of the slats. For gates (parameter 151 set to 3 or 4) the parameter determines time after which open gate will start closing automatically (if set to 0, gate will not close). The parameter is irrelevant for other modes. | 0 | 4 | 0 | 0 | 150 | From | To | Description |
|---|
0 | 965535 | time of turn |
|
153 | Set slats back to previous position | For Venetian blinds (parameter 151 set to 2) the parameter determines slats positioning in various situations. The parameter is irrelevant for other modes. NOTE: If parameter 20 is set to 1 (toggle switch), change value of parameter 153 to 0 for slats to work properly. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
0 | 0 | slats return to previously set position only in case of the main controller operation. | 1 | 1 | slats return to previously set position in case of the main controller operation, momentary switch operation, or when the limit switch is reached. | 2 | 2 | slats return to previously set position in case of the main controller operation, momentary switch operation, when the limit switch is reached or after receiving the Switch Multilevel Stop control frame |
|
155 | Motor operation detection | Power threshold to be interpreted as reaching a limit switch. | 0 | 2 | 0 | 0 | 10 | From | To | Description |
|---|
0 | 0 | reaching a limit switch will not be detected | 1 | 255 | report interval |
|
156 | Time of up movement | This parameter determines the time needed for roller blinds to reach the top. For modes with positioning value is set automatically during calibration, otherwise it must be set manually. | 0 | 4 | 0 | 0 | 6000 | From | To | Description |
|---|
1 | 65535 | (0.01 - 655.35s, every 0.01s) - movement time |
|
157 | Time of down movement | This parameter determines time needed for roller blinds to reach the bottom. For modes with positioning value is set automatically during calibration, otherwise it must be set manually. | 0 | 4 | 0 | 0 | 6000 | From | To | Description |
|---|
1 | 65535 | (0.01 - 655.35s, every 0.01s) - movement time |
|
154 | Delay motor stop after reaching end switch | For blinds (parameter 151 set to 1, 2, 5 or 6) the parameter determines the time after which the motor will be stopped after end switch contacts are closed. For gates (parameter 151 set to 3 or 4) the parameter determines time after which the gate will start closing automatically if S2 contacts are opened (if set to 0, gate will not close). | 0 | 2 | 0 | 0 | 10 | From | To | Description |
|---|
0 | 255 | time |
|