7 | Overload Protection | Set the amp level for overload protection to kick in. The number entered as the value corresponds to the total number of amps the Double Plug needs to detect across both outlets to turn off automatically and send a notification to the hub and associated devices. | 0 | 1 | 0 | 0 | 10 | From | To | Description |
|---|
1 | 10 | number of Amps |
|
8 | Enable / Disable Auto Turn-Off Timer for CH1 | Use this parameter to enable or disable the auto turn-off timer for the left (CH1) outlet. If this feature is enabled, the device connected to CH1 outlet will automatic er a fixed period of time from being turned on (set in parameter 9). | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | timer disabled | 1 | 1 | timer enabled |
|
1 | On/Off Status Recovery A er Power Failure | Choose the recovery state for your Double Plug’s outlets if power outage occurs. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | Double Plug remembers the status for each outlet prior to power outage and turns back to it | 1 | 1 | Double Plug automatically turns ON for each outlet once power is restored (it does not remember the status prior to power outage) | 2 | 2 | Double Plug automatically turns OFF each outlet once power is restored (it does not remember the status prior to power outage) |
|
9 | Set Auto Turn-Off Timer for CH1 | Use this parameter to set the time after which you want the device connected to the left (CH1) outlet to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes. | 0 | 4 | 0 | 0 | 60 | From | To | Description |
|---|
1 | 65535 | minutes |
|
10 | Enable / Disable Auto Turn-On Timer for CH1 | Use this parameter to set the time after which you want the device connected to the left (CH1) outlet to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | timer disabled | 1 | 1 | timer enabled |
|
11 | Set Auto Turn-On Timer for CH1 | Use this parameter to set the time after which you want the device connected to the left (CH1) outlet to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes. | 0 | 1 | 0 | 0 | 60 | From | To | Description |
|---|
1 | 65535 | minutes |
|
2 | Power Wattage Report Value Threshold | Choose how you want your Double Plug to report power consumption to your hub. The number entered as value corresponds to the number of Watts the appliance needs to go over for the change to be reported. So if 5 Watts are entered by default, the Double Plug will report any change in power usage over 5 Watts for each outlet (whether it’s at least 5 Watts more or 5 Watts less compared to previous report). | 0 | 4 | 0 | 0 | 5 | From | To | Description |
|---|
0 | 0 | disabled (Double Plug will not report power consumption based on this setting). | 1 | 65535 | number of Watts the appliance needs to go over for the change to be reported |
|
4 | Energy (kWh) Report Frequency | Choose how often you want your Double plug to report power consumption (W) to your controller (hub). The number entered as value corresponds to the number of seconds. So if 300 is entered by default, the Double Plug will report energy usage every 300 seconds (5 minutes). | 0 | 4 | 0 | 0 | 300 | From | To | Description |
|---|
5 | 2678400 | interval for energy (kwh) reports in seconds |
|
5 | Voltage (V) Report Frequency | Choose how often you want your Double plug to report voltage to your controller (hub). The number entered as value corresponds to the number of seconds. So if 300 is entered by default, the Double Plug will report voltage every 300 seconds (5 minutes). | 0 | 4 | 0 | 0 | 300 | From | To | Description |
|---|
5 | 2678400 | interval for voltage (V) reports in seconds |
|
6 | Electrical Current (A) Report Frequency | Choose how often you want your Double plug to report electrical current (A) to your controller (hub). The number entered as value corresponds to the number of seconds. So if 300 is entered by default, the Double Plug will report current every 300 seconds (5 minutes). | 0 | 4 | 0 | 0 | 300 | From | To | Description |
|---|
5 | 2678400 | interval for electrical current (A) reports in seconds |
|
17 | LED Indicator Mode | Choose if you want the LED indicators next to each outlet to come on when power is on or off, or if you want to disable them. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
0 | 0 | LED indicator will display power consumption whenever the device is plugged in (LED stays on at all times, even if the plug is off) | 1 | 1 | LED indicator will display power consumption whenever the device is ON in and will turn off when the plug is OFF | 2 | 2 | LED indicator will display the level of power consumption for 5 seconds only whenever the device is turned on or off (LED indicator will stay off for most of the time) | 3 | 3 | LED indicator is OFF at all times except for inclusion, exclusion, and Z-Wave range test. |
|