| Product Recognition | |
|---|
| Certification Number | ZC10-17025428 |
|---|
| Name | SHP-DS700MK |
|---|
| Short Description | Samsung Digital Doorlock / Black |
|---|
| Long Description | Touch Screen Type Door Lock.
The Samsung SDS Z-Wave Door Lock is a security enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate to other security enable Z-Wave Plus products. |
|---|
| Brand | SAMSUNG SDS |
|---|
| Product Identifier | SHP-DS700MK |
|---|
| OEM Version | HW: 1 FW: 1.03 |
|---|
| Hardware Platform | ZM5101 |
|---|
| Z-Wave Version | 6.51.06 |
|---|
| Library Type | SLAVE_ENHANCED_232 |
|---|
| Device Type | Door Lock - Keypad |
|---|
| Role Type | ROLE_TYPE_SLAVE_SLEEPING_LISTENING |
|---|
| Manufacturer ID | 0x022E |
|---|
| Product Type ID | 0x0001 |
|---|
| Product ID | 0x0001 |
|---|
| User Icon | 0x0300 |
|---|
| Installer Icon | 0x0300 |
|---|
| Frequency Plans | KR: 920.90MHz, 921.70MHz, 923.10MHz |
|---|
| Categories | Locks |
|---|
| Countries / Regions | Republic of Korea |
|---|
| Supported Command Classes | | Identifier | Name | Key | Version |
|---|
| COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | | COMMAND_CLASS_USER_CODE | User Code | 0x63 | 1 | | COMMAND_CLASS_DOOR_LOCK_V2 | Door Lock V2 | 0x62 | 2 | | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | | COMMAND_CLASS_TIME_PARAMETERS | Time Parameters | 0x8B | 1 | | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | | COMMAND_CLASS_TIME_V2 | Time V2 | 0x8A | 2 | | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 | Firmware Update Meta-Data V2 | 0x7A | 2 | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | | COMMAND_CLASS_NOTIFICATION_V4 | Notification V4 | 0x71 | 4 | | COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V3 | Schedule Entry Lock V3 | 0x4E | 3 |
|
|---|
| Documents | |
|---|
| Features | | Feature | Values |
|---|
| Battery Quantity | | | Color | | | Battery Type | | | Door Lock Type | |
|
|---|
| Association Groups | | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
| 1 | 1 | 0 | Z-Wave Plus Lifeline |
|
|---|
| Texts | | ID | Description | Value |
|---|
| 6 | Additional Special Features | Privacy Mode Function, Setting the Security Function, Lockout Mode, Intrusion Detection Function, Sound Setting | | 5 | Factory Reset | All registered Master/User data will be deleted, and Master PIN Code is set to ‘1234’. Also Z-Wave Door Lock is being removed from a network.
① Press the [REG] button for 3 seconds. (Ding dong -> Ding ding)
② Press the [*] button after pressing the [4567890123] button.
(Success: Ding ding dang, Fail : Ding dong Ding dong)
※ Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. | | 1 | Inclusion | ① Click [Add] icon in Z-Wave PC Conroller Program.
② Press the [REG] button for 3 seconds. (Ding dong -> Ding ding)
③ Press the [*] button after pressing the [00[*] button.
( Success : Ding dong dang, Fail : Ding dong Ding dong ) | | 2 | Exclusion | After exclusion from Z-Wave Network, it will no longer be remotely-controlled via the controller.
① Click [Remove] icon in Z-Wave PC Controller Program.
② Press the [REG] button for 3 seconds. (Ding dong -> Ding ding)
③ Press the [*] button after pressing the [00] button.
(Success : Ding dong dang, Fail : Ding dong Ding dong) |
|
|---|
| Supports NWI | Yes |
|---|
| Supports Explorer Frames | Yes |
|---|
| Is Flirs | Yes |
|---|