| Product Recognition | |
|---|
| Certification Number | ZC10-16115310 |
|---|
| Name | Single Function Magnetic Sensor |
|---|
| Short Description | The door/window sensor PSM08 has door/window sensor function. |
|---|
| Long Description | The door/window sensor PSM08 has door/window sensor function,based on Z-Wave™ technology. |
|---|
| Brand | Philio |
|---|
| Product Identifier | PSM08 |
|---|
| OEM Version | HW: 1 FW: 1.02 |
|---|
| Hardware Platform | SD3502 |
|---|
| Z-Wave Version | 6.61.00 |
|---|
| Library Type | SLAVE_ENHANCED_232 |
|---|
| Device Type | Notification Sensor |
|---|
| Role Type | ROLE_TYPE_SLAVE_SLEEPING_REPORTING |
|---|
| Manufacturer ID | 0x013C |
|---|
| Product Type ID | 0x0002 |
|---|
| Product ID | 0x0036 |
|---|
| User Icon | 0x0C06 |
|---|
| Installer Icon | 0x0C06 |
|---|
| Frequency Plans | US: 916.00MHz, 908.40MHz |
|---|
| Categories | Sensors |
|---|
| Countries / Regions | United States of America |
|---|
| Supported Command Classes | | Identifier | Name | Key | Version |
|---|
| COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | | COMMAND_CLASS_NOTIFICATION_V4 | Notification V4 | 0x71 | 4 |
|
|---|
| Documents | | Category | Description | File |
|---|
| Manual_Primary_Lang | Product or Owner's Manual | PSM08_Manual.pdf |
|
|---|
| Features | | Feature | Values |
|---|
| Battery Quantity | | | Battery Type | | | Sensors | | Value |
|---|
| Open/Closed (Binary) |
| | Color | |
|
|---|
| Association Groups | | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
| 1 | 1 | 0 | Z-Wave Plus Lifeline |
|
|---|
| Texts | | ID | Description | Value |
|---|
| 1 | Inclusion | There is a button on PSM08.
1. Have Z-Wave™ Controller entered inclusion mode.
2. Pressing button once to enter the inclusion mode.
3. After add successful, the device will wake to receive the setting command from Z-Wave™ Controller about 20 seconds. | | 2 | Exclusion | There is a button on PSM08.
1. Have Z-Wave™ Controller entered exclusion mode.
2. Pressing button once to enter the exclusion mode. | | 5 | Factory Reset | There is a button on PSM08.
1. Pressing button for about 5 seconds.
2. IDs are excluded and all settings will reset to factory default.
Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. | | 4 | Device Wake-Up | There is a button on PSM08.
Press the button once, the device will awake 10 seconds. |
|
|---|
| Supported Multilevel Sensors | | Multilevel Sensor Type |
|---|
| 0x02 |
|
|---|
| Supports NWI | Yes |
|---|
| Supports Explorer Frames | Yes |
|---|