7 | Default Siren On Mode | This parameter defines the default sound index, volume and the duration time for siren on. This parameter can be selected between ALARM SOUND and DOOR BELL SOUND. The settings for ALARM SOUND MODE defines by Param #1, #2 and #5. The settings for DOOR BELL SOUND MODE defines by Param #3, #4 and #6. If parameter is set to ‘1’, siren will select ALARM SOUND MODE to play sound; If parameter is set to ‘2’, siren will select DOOR BELL SOUND MODE to play sound; | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
1 | 2 | Default Siren On Mode |
|
8 | Alarm Led Enable | This parameter defines the default led enable status when siren is on for ALARM SOUND MODE. If parameter is set to ‘0’, led will be disable. If parameter is set t0 ‘1’, led will be enable. When siren is on, the led will blink. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
0 | 1 | Alarm mode switching |
|
5 | Alarm Sound Index | This parameter defines the alarm sound index for siren play different sound when alarm occurs. There are 10 different sound for user selection. | 0 | 1 | 0 | 0 | 10 | From | To | Description |
|---|
1 | 10 | Alarm Sound Index |
|
3 | Door Bell Sound Duration Time | This parameter defines the door bell sound duration time when siren receives a door/window sensor notification report or an alarm command (BASIC_SET = 0x02) from controller. The door bell sound will be played always if this parameter is set to ‘0x7F’. The door bell sound will not be played if this parameter is set to ‘0’. Other values are the door bell sound playing duration time. Unit: Time. The value for this parameter is unsigned value. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
0 | 127 | Door Bell Sound Duration Time |
|
4 | Door Bell Sound Volume | This parameter defines the output volume when siren plays alarm sound. Door Bell sound volume is divided into 3 stages: Low (Parameter is set to ‘1’), Middle (Parameter is set to ‘2’), High(Parameter is set to ‘3’). Default value is ‘1’. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
1 | 3 | Door Bell Sound Volume |
|
6 | Door Bell Sound Index | This parameter defines the door bell sound index for siren play different sound when alarm occurs. There are 10 different sound for user selection. | 0 | 1 | 0 | 0 | 9 | From | To | Description |
|---|
1 | 10 | Door Bell Sound Index |
|
1 | Alarm Sound Volume | This parameter defines the output volume when siren plays door bell sound. Door Bell sound volume is divided into 3 stages, Low (Parameter is set to ‘1’), Middle (Parameter is set to ‘2’), High (Parameter is set to ‘3’). Default value is ‘3’. | 0 | 1 | 0 | 0 | 3 | From | To | Description |
|---|
1 | 3 | Alarm Sound Volume |
|
2 | Alarm Sound Duration Time | This Parameter defines the alarm sound duration time when siren receive an alarm sensor notification report or an alarm command from controller. The duration time is divided into 5 stages: ◆ Siren is not on (Parameter is set to ‘0’), ◆ 30 second (Parameter is set to ‘1’), ◆ 1 minute (Parameter is set to ‘2’), ◆ 5 minute (Parameter is set to ‘3’) ◆ Siren is always on until battery is dead (Parameter is set to ‘0x7F’). Default value is ‘2’. The value for this parameter is unsigned value. | 0 | 1 | 0 | 0 | 2 | From | To | Description |
|---|
127 | 127 | Always alarm | 0 | 3 | Alarm Sound Duration Time |
|
9 | Door Bell Led Enable | This parameter defines the default led enable status when siren is on for DOOR BELL SOUND MODE. If parameter is set to ‘0’, led will be disable. If parameter is set t0 ‘1’, led will be enable. When siren is on, the led will blink. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 1 | Door Bell Led Enable |
|