Product Recognition | |
|---|
Certification Number | ZC10-17085749 |
|---|
Name | Siterwell Power plug Sensor |
|---|
Short Description | Smart power plug can control the on/off of electric appliance on mobile app. detect the current, voltage, accumulated voltage and offer overload protection. |
|---|
Long Description | This product can be included and operated in any Z‐Wave network with other Z‐Wave certified devices from other manufacturers and/or other applications. All non‐battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
In the front casing, there is button that is used to carry out include, exclude or reset factory default settings on PCB Board.
When power is first supplied, the LED will flash on and off with yellow alternately every 1 second intervals within 5 seconds if the detector has not been added a Z‐Wave network, otherwise the LED will flash on and off 5 times with cyan alternately every 300 millisecond. Please get familiar with the terms below before starting the operations.
This Plug has function that remembers the relay states, the plug will turn on after power up next time if the plug is turn on before the power cut‐off. |
|---|
Brand | Siterwell Technology |
|---|
Product Identifier | STW-W3350WU |
|---|
OEM Version | HW: 65 FW: 3.70 |
|---|
Hardware Platform | ZM5202 |
|---|
Z-Wave Version | 6.51.06 |
|---|
Library Type | SLAVE_ENHANCED_232 |
|---|
Device Type | On/Off Power Switch |
|---|
Role Type | ROLE_TYPE_SLAVE_ALWAYS_ON |
|---|
Manufacturer ID | 0x0266 |
|---|
Product Type ID | 0x0003 |
|---|
Product ID | 0x0350 |
|---|
User Icon | 0x0700 |
|---|
Installer Icon | 0x0700 |
|---|
Frequency Plans | EU: 869.85MHz, 868.40MHz |
|---|
Categories | Energy Meters, All Lighting Devices, On/Off Switches/Devices |
|---|
Countries / Regions | European Union |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_SWITCH_ALL | Switch All | 0x27 | 1 | COMMAND_CLASS_SWITCH_BINARY | Switch Binary | 0x25 | 1 | COMMAND_CLASS_BASIC | Basic | 0x20 | 1 | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC | Manufacturer Specific | 0x72 | 1 | COMMAND_CLASS_NOTIFICATION_V4 | Notification V4 | 0x71 | 4 | COMMAND_CLASS_METER_V4 | Meter V4 | 0x32 | 4 |
|
|---|
Controlled Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_BASIC | Basic | 0x20 | 1 |
|
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Color | | Switch Load Capacity Volt-Ampere | | Supported Meter Type | | Switch Type | | Supported Notification Types | | Firmware Updatable | Value |
|---|
Updatable by Manufacturer |
|
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
1 | 5 | 0 | GROUP 1 is lifeline service that assigned to plug status – ON/OFF. It enables the Plug to send reports and readings to Z‐Wave Controller or Z‐Wave Gateway. This Group Support:
NOTIFICATION_REPORT_V4 METER_REPORT_V4 SWITCH_BINARY_REPORT DEVICE_RESET_LOCALLY_NOTIFICATION | 2 | 5 | 0 | GROUP 2 allows for sending control commands to associated devices such as Siren, relay module, lighting, etc. If current load is over the max current defined in parameter #3, the Plug will send a BASIC_SET (0xFF) to associated devices. When current load is normal, plug will send a BASIC_SET (0x00) to associated devices. This Group Support:
BASIC_SET | 3 | 5 | 0 | GROUP 3 allows for Send Notification to associated devices in this group. This Group Support: NOTIFICATION_REPORT_V4 |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
9 | Time switch Configure | This parameter defines the time period that plug time switch off. This parameter can be configured 1 ~ 65535(in minutes). If Parameter #9 is set to ‘1’, and relay is turn‐on, the relay will be turn‐off after delay this parameter. | 0 | 2 | 0 | 0 | 150 | From | To | Description |
|---|
1 | 65535 | minutes | 0 | 0 | |
| 6 | Meter Reporting Setting | This parameter defines by how much current changed must change to be reported to the Z‐Wave Controller or Z‐Wave Gateway, in percents. If the rate of current change ratio is greater than this parameter, the plug will report the results, voltage, current, power and energy, that plug measure to Z‐Wave Controller or Z‐Wave Gateway. | 0 | 1 | 0 | 0 | 5 | | 8 | Time switch Configure | This parameter defines the timer function Enable/Disable. This parameter can be configured with 0 or 1, where 0 means disable time switch function and 1 enable. The time period will be defined in parameter #9. If this parameter is Set to 1, and when turn the plug relay on, the timer in plug start run with time period defined in parameter #9 and the plug will turn the relay off. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | Time switch Disable | 1 | 1 | Time switch Enable |
| 10 | Enable Button On/Off | This parameter defines the button on/off function is enabled or not on the top of the wall plug. This parameter can be configured 0 and 1. If this parameter is set to ‘1’, users can turn on and off the wall plug by pressing the button on the top of the wall plug. If this parameter is set to ‘0’, the wall plug cannot be turned on and off by pressing the button. | 0 | 1 | 0 | 0 | 1 | | 1 | Meter Report Enable | This parameter defines Disable/Enable meter report measure data to controller. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
0 | 0 | Disable Report | 1 | 1 | Enable Report |
| 7 | Remember Relay Status | This parameter defined the relay status if remember or not. If remembered, the plug will restore the relay status last power off when the plug supply power next time. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
1 | 1 | emember the Relay Status. | 0 | 0 | Don’t Remember, the relay will keep OFF when Plug Supply Power |
| 5 | LED Enable/Disable | This parameter defines the LED indication Function ON/OFF. This parameter can be configured with 0 or 1, where 0 means disable LED indication Function and will always be turn‐off, and 1 means enable LED Function. | 0 | 1 | 0 | 0 | 1 | | 2 | Set Report Interval | This parameter defines interval time (in seconds) that Meter report data to main controller. | 0 | 2 | 0 | 0 | 300 | From | To | Description |
|---|
1 | 65535 | s | 0 | 0 | |
|
|
|---|
Texts | ID | Description | Value |
|---|
1 | Inclusion | Add the Device (Smart Plug) to Z‐Wave Network
1.Make sure the sensor is powered.
2.Set Z‐Wave controller or Z‐Wave gateway into inclusion mode (Refer to the controller or gateway operating manual)
3.Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off with green alternately five times within 2 seconds. | 2 | Exclusion | Delete the Device (Smart Plug) from Z‐Wave Network
1.Make sure the sensor is powered.
2.Set Z‐Wave controller or Z‐Wave gateway into exclusion mode (Refer to the controller or gateway operating manual)
3.Press the button three times within 1.5 second, the device will enter exclusion mode. And the LED will flash on and off with yellow alternately five times within 2 seconds. | 5 | Factory Reset | Note: to use the reset procedure only when the primary controller is missing or inoperable.
Restore the Device (Smart Plug) to Factory Default Settings
Reset procedure will delete all information on the Z‐Wave network and Z‐Wave controller or Z‐Wave Gateway, and restore the sensor to factory default settings.
1.Make sure the sensor is powered.
2.Press and hold the button more than 10 seconds until the LED blink with red color.
3.Release the button. |
|
|---|
Supported / Controlled Meter Types | Meter Type | Rate Type | Description |
|---|
Electric meter | Import | Electric Meter Consumption |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Power Management | (Refer to parameters): State idle |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|