Product Recognition | |
|---|
Certification Number | ZC10-18026005 |
|---|
Name | Slim Multisensor |
|---|
Short Description | The slim multisensor PST02-1B has PIR, temperature and illumination, 3 sensors function in one,based on Z-Wave technology |
|---|
Long Description | The slim multisensor PST02-1B has PIR, temperature and illumination, 3 sensors function in one,based on Z-Wave technology
It is the Z-WaveTM plus product, it support the security, OTA... Those
newest features of the Z-WaveTM technology. Z-WaveTM is a wireless
communication protocol designed for home automation, specifically to
remotely control applications in residential and light commercial
environments. The technology uses a low-power RF radio embedded or
retrofitted into home electronics devices and systems, such as lighting,
home access control, entertainment systems and household appliances. |
|---|
Brand | Philio Technology |
|---|
Product Identifier | PST02-1B |
|---|
OEM Version | HW: 1 FW: 1.29:01.20 |
|---|
Hardware Platform | SD3502 |
|---|
Z-Wave Version | 6.51.02 |
|---|
Library Type | SLAVE_ENHANCED_232 |
|---|
Device Type | Notification Sensor |
|---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_REPORTING |
|---|
Manufacturer ID | 0x013C |
|---|
Product Type ID | 0x0002 |
|---|
Product ID | 0x000D |
|---|
User Icon | 0x0C07 |
|---|
Installer Icon | 0x0C07 |
|---|
Frequency Plans | RU: 869.00MHz |
|---|
Categories | Sensors |
|---|
Countries / Regions | Russian Federation |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | Sensor Multilevel V5 | 0x31 | 5 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_SENSOR_BINARY_V2 | Sensor Binary V2 | 0x30 | 2 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 | Firmware Update Meta-Data V2 | 0x7A | 2 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_NOTIFICATION_V4 | Notification V4 | 0x71 | 4 | COMMAND_CLASS_MULTI_CMD | Multi-Command | 0x8F | 1 |
|
|---|
Controlled Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_BASIC | Basic | 0x20 | 1 | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | COMMAND_CLASS_MULTI_CMD | Multi-Command | 0x8F | 1 |
|
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Sensors | Value |
|---|
Air Temperature | Luminance |
| Supported Notification Types | |
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
2 | 8 | 0 | The group 2 is for light
control, the device will send the “Basic Set” command
to this group. | 1 | 8 | 0 | The group 1 is for
receiving the report message, like triggered event,
temperature, illumination etc. |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
2 | Basic Set Level | Setting the BASIC command value to turn on the light. The 0xFF(-1) means turn on the light. For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light. Caution: The value is unsigned byte, the range is from 0x00 ~ 0xFF. | 0 | 1 | 0 | 0 | -127 | From | To | Description |
|---|
-128 | 127 | Setting the BASIC command value to turn on the light. The 0xFF(-1) means turn on the light. For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light. Caution: The value is unsigned byte, the range is from 0x00 ~ 0xFF. |
| 4 | Light Threshold | Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower then the threshold, the device will turn on the light. 0 means turn off illumination detected function. And never turn on the light. 1 means darkest. 99 means brightest. 100 means turn off illumination detected function. And always turn on the light. Notice: In none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value. | 0 | 1 | 0 | 0 | 99 | From | To | Description |
|---|
0 | 100 | 0 means turn off illumination detected function. And never turn on the light. 1 means darkest. 99 means brightest. 100 means turn off illumination |
| 5 | Operation Mode | Operation mode. Using bit to control. Caution: The value is unsigned byte, the range is from 0x00 ~ 0xFF. Bit1: 1 means test mode, 0 means normal mode Bit3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius Bit4: Disable the illumination report after event triggered. (1:Disable, 0:Enable) Bit5: Disable the temperature report after event triggered. (1:Disable, 0:Enable) Bit7: Disable the back key release into test mode. (1:Disable, 0:Enable) | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
1 | 1 | 1 means test mode, 0 means normal mode. | 5 | 5 | Bit5: Disable the temperature report after event triggered. (1:Disable, 0:Enable) | 7 | 7 | Bit7: Disable the back key release into test mode. (1:Disable, 0:Enable) | 3 | 3 | Bit3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius | 4 | 4 | Bit4: Disable the illumination report after event triggered. (1:Disable, 0:Enable) |
| 6 | Mult- Sensor Function Switch | Multisensor function switch. Using bit to control. Caution: The value is unsigned byte, the range is from 0x00 ~ 0xFF. Bit1: Disable PIR integrate Illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable) | 0 | 1 | 0 | 0 | 4 | From | To | Description |
|---|
2 | 2 | Disable PIR integrate Illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable) |
| 7 | Customer Function | Customer function switch, using bit control. Caution: The value is unsigned byte, the range is from 0x00 ~ 0xFF. Bit1: Enable sending motion OFF report. (0:Disable, 1:Enable) Note: Depends on the Bit4, 0: Report Notification CC, Type: 0x07, Event: 0xFE 1: Sensor Binary Report, Type: 0x0C, Value: 0x00 Bit2: Enable PIR super sensitivity mode. (0:Disable, 1:Enable) Bit4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report Bit5: Disable Multi CC in auto report. (1:Disable, 0:Enable) Bit6: Disable to report battery state when the device triggered. (1:Disable, 0:Enable) | 0 | 1 | 0 | 0 | 4 | From | To | Description |
|---|
1 | 1 | Bit1: Enable sending motion OFF report. (0:Disable, 1:Enable) | 2 | 2 | Bit2: Enable PIR super sensitivity mode. (0:Disable, 1:Enable) | 4 | 4 | Bit4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report. | 5 | 5 | Bit5: Disable Multi CC in auto report.(1:Disable, 0:Enable) | 6 | 6 | Bit6: Disable to report battery state when the device triggered. (1:Disable, 0:Enable) |
| 9 | Turn Off Light Time | After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. 8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command. | 0 | 1 | 0 | 0 | 4 | From | To | Description |
|---|
0 | 127 | After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. 8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command |
| 8 | PIR Re- Detect Interval Time | In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default tick is 3 (24 seconds). Setting the suitable value to prevent received the trigger signal too frequently. Also can save the battery energy. Notice: If this value bigger than the configuration setting NO. 9. There is a period after the light turned off and the PIR not start detecting. | 0 | 1 | 0 | 0 | 3 | From | To | Description |
|---|
1 | 127 | In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default tick is 3 (24 seconds). |
| 3 | PIR Sensitivity | PIR sensitivity settings. 0 means disable the PIR motion. 1 means the lowest sensitivity, 99 means the highest sensitivity. High sensitivity means can detected long distance, but if there is more noise signal in the environment, it will re-trigger too frequency. | 0 | 1 | 0 | 0 | 80 | From | To | Description |
|---|
0 | 99 | PIR sensitivity settings. 0 means disable the PIR motion. 1 means the lowest sensitivity, 99 means the highest sensitivity. High sensitivity means can detected long distance, but if there is more noise signal in the environment, it will re-trigger too frequency. |
|
|
|---|
Texts | ID | Description | Value |
|---|
1 | Inclusion | There are two tamper keys in the device, one is in the back side,
another is in the front side. Both of them can add, remove or reset from Z-WaveTM network.
1. Have Z-WaveTM Controller entered inclusion mode.
2. Pressing tamper key three times within 1.5 seconds
to enter the inclusion mode.
3. After add successful, the device will wake to
receive the setting command from Z-WaveTM
Controller about 20 seconds | 2 | Exclusion | There are two tamper keys in the device, one is in the back side,
another is in the front side. Both of them can add, remove or reset from Z-WaveTM network.
1. Have Z-WaveTM Controller entered exclusion mode.
2. Pressing tamper key three times within 1.5 seconds
to enter the exclusion mode.
Node ID has been excluded. | 5 | Factory Reset | 1. Pressing tamper key four times within 1.5 seconds
and do not release the tamper key in the 4th
pressed, and the LED will light ON.
2. After 3 seconds the LED will turn OFF, after that
within 2 seconds, release the tamper key. If
successful, the LED will light ON one second.
Otherwise, the LED will flash once.
3. IDs are excluded and all settings will reset to
factory default. | 4 | Device Wake-Up | After the device adding to the network, it will wake-up once per day in
default. When it wake-up it will broadcast the “Wake Up Notification”
message to the network, and wake-up 10 seconds for receive the
setting commands.
The wake-up interval minimum setting is 30 minutes, and maximum
setting is 120 hours. And the interval step is 30 minutes.
If the user want to wake-up the device immediately, please remove the
front cover,and press the tamper key once. The device will wake-up 10
seconds. |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Home Security | (Refer to parameters): State idle |
|
|---|
Supported Multilevel Sensors | Multilevel Sensor Type |
|---|
Air temperature | Illuminance |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|