Product Recognition | |
|---|
Certification Number | ZC10-18026016 |
|---|
Name | Slim Multisensor |
|---|
Short Description | The slim multisensor PST02-1C has door/window, temperature and illumination, 3 sensors function in one,based on Z-Wave technology |
|---|
Long Description | The slim multisensor PST02-1C has door/window, temperature and illumination, 3 sensors function in one,based on Z-Wave technology
It is the Z-WaveTM plus product, it support the security, OTA... Those
newest features of the Z-WaveTM technology. Z-WaveTM is a wireless
communication protocol designed for home automation, specifically to
remotely control applications in residential and light commercial
environments. The technology uses a low-power RF radio embedded or
retrofitted into home electronics devices and systems, such as lighting,
home access control, entertainment systems and household appliances. |
|---|
Brand | Philio Technology |
|---|
Product Identifier | PST02-1C |
|---|
OEM Version | HW: 1 FW: 1.29:01.20 |
|---|
Hardware Platform | SD3502 |
|---|
Z-Wave Version | 6.51.02 |
|---|
Library Type | SLAVE_ENHANCED_232 |
|---|
Device Type | Notification Sensor |
|---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_REPORTING |
|---|
Manufacturer ID | 0x013C |
|---|
Product Type ID | 0x0002 |
|---|
Product ID | 0x000E |
|---|
User Icon | 0x0C07 |
|---|
Installer Icon | 0x0C07 |
|---|
Frequency Plans | RU: 869.00MHz |
|---|
Categories | Sensors |
|---|
Countries / Regions | Russian Federation |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | Sensor Multilevel V5 | 0x31 | 5 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_SENSOR_BINARY_V2 | Sensor Binary V2 | 0x30 | 2 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 | Firmware Update Meta-Data V2 | 0x7A | 2 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_NOTIFICATION_V4 | Notification V4 | 0x71 | 4 | COMMAND_CLASS_MULTI_CMD | Multi-Command | 0x8F | 1 |
|
|---|
Controlled Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_BASIC | Basic | 0x20 | 1 | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 |
|
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Sensors | Value |
|---|
Air Temperature | Luminance |
| Supported Notification Types | |
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
1 | 8 | 0 | The group 1 is for
receiving the report message, like triggered event,
temperature, illumination etc. | 2 | 8 | 0 | The group 2 is for light
control, the device will send the “Basic Set” command
to this group. |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
2 | Basic Set Level | Setting the BASIC command value to turn on the light. The 0xFF(-1) means turn on the light. For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light. Caution: The value is unsigned byte, the range is from 0x00 ~ 0xFF. | 0 | 1 | 0 | 0 | -127 | From | To | Description |
|---|
-127 | 127 | Setting the BASIC command value to turn on the light. The 0xFF(-1) means turn on the light. For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light. Caution: The value is unsigned byte, the range is from 0x00 ~ 0xFF. |
| 6 | Mult- Sensor Function Switch | Multisensor function switch. Using bit to control. Caution: The value is unsigned byte, the range is from 0x00 ~ 0xFF. Bit0: Disable magnetic integrate illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable) Bit4: Disable delay 5 seconds to turn off the light, when door/window Bit5: Disable auto turn off the light, after door/window opened to turn on the light. (1:Disable, 0:Enable) Notice: If bit2 is zero, this setting is useless. Notice: If the configuration No.9 is zero, this setting is useless. | 0 | 1 | 0 | 0 | 4 | From | To | Description |
|---|
0 | 0 | Bit0: Disable magnetic integrate illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable) | 4 | 4 | Bit4: Disable delay 5 seconds to turn off the light, when door/window | 5 | 5 | Bit5: Disable auto turn off the light, after door/window opened to turn on the light. (1:Disable, 0:Enable) Notice: If bit2 is zero, this setting is useless. Notice: If the configuration No.9 is zero, this setting is useless. |
| 7 | Customer Function | Customer function switch, using bit control. Caution: The value is unsigned byte, the range is from 0x00 ~ 0xFF Bit3: Disable send out BASIC OFF after door closed. (1:Disable, 0:Enable) Bit4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report Bit5: Disable Multi CC in auto report. (1:Disable, 0:Enable) Bit6: Disable to report battery state when the device triggered. (1:Disable, 0:Enable) | 0 | 1 | 0 | 0 | 4 | From | To | Description |
|---|
3 | 3 | Bit3: Disable send out BASIC OFF after door closed. (1:Disable, 0:Enable) | 5 | 5 | Bit5: Disable Multi CC in auto report. (1:Disable, 0:Enable) | 6 | 6 | Bit6: Disable to report battery state when the device triggered. (1:Disable, 0:Enable) | 4 | 4 | Bit4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report |
| 5 | Operation Mode | Operation mode. Using bit to control. Caution: The value is unsigned byte, the range is from 0x00 ~ 0xFF. Bit1: 1 means test mode, 0 means normal mode. Notice: This bit only effect by the DIP Switch setting to “customer mode”, otherwise it decides by DIP Switch setting to Test or Normal Mode. Bit2: Disable the door/window function. (1:Disable, 0:Enable) Bit3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius Bit4: Disable the illumination report after event triggered. (1:Disable, 0:Enable) Bit5: Disable the temperature report after event triggered. (1:Disable, 0:Enable) | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
2 | 2 | Disable the door/window function. (1:Disable, 0:Enable) | 1 | 1 | Bit1: 1 means test mode, 0 means normal mode. Notice: This bit only effect by the DIP Switch setting to “customer mode”, otherwise it decides by DIP Switch setting to Test or Normal Mode. | 3 | 3 | Bit3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius | 4 | 4 | Bit4: Disable the illumination report after event triggered. (1:Disable, 0:Enable) | 5 | 5 | Bit5: Disable the temperature report after event triggered. (1:Disable, 0:Enable) |
| 9 | Turn Off Light Time | After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. 8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command | 0 | 1 | 0 | 0 | 4 | From | To | Description |
|---|
0 | 127 | After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. 8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command |
| 4 | Light Threshold | Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower then the threshold, the device will turn on the light. 0 means turn off illumination detected function. And never turn on the light. 1 means darkest. 99 means brightest. 100 means turn off illumination detected function. And always turn on the light. Notice: In none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value. | 0 | 1 | 0 | 0 | 99 | From | To | Description |
|---|
0 | 100 | Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower then the threshold, the device will turn on the light. 0 means turn off illumination detected function. And never turn on the light. 1 means darkest. 99 means brightest. 100 means turn off illumination detected function. And always turn on the light. Notice: In none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value. |
|
|
|---|
Texts | ID | Description | Value |
|---|
5 | Factory Reset | Notice: Use this procedure only in the event
that the primary controller is lost or otherwise inoperable.
1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key on the 4th press, the LED lite will ON.
2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second.
Otherwise, the LED will flash once.
3. IDs are excluded and all settings will reset to factory default. | 1 | Inclusion | 1. Have Z-WaveTM Controller enter inclusion mode.
2. Pressing tamper key three times within 1.5 seconds
will enter the inclusion mode.
3. After add successful, the device will wake to receive the setting command from Z-WaveTM Controller, about 20 seconds | 2 | Exclusion | 1. Have Z-WaveTM Controller enter exclusion mode.
2. Pressing tamper key three times within 1.5 seconds will enter the exclusion mode.
Node ID has been excluded. | 4 | Device Wake-Up | After the device adding to the network, it will wake-up once per day in
default. When it wakes-up it will broadcast the “Wake Up Notification”
message to the network, and wake-up 10 seconds to receive the
setting commands.
The wake-up interval minimum setting is 30 minutes, and maximum
setting is 120 hours. And the interval step is 30 minutes.
If the user want to wake-up the device immediately, please remove the
front cover, and press the tamper key once. The device will wake-up 10
seconds. |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Home Security | (Refer to parameters): State idle |
|
|---|
Supported Multilevel Sensors | Multilevel Sensor Type |
|---|
Air temperature | Illuminance |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|