| 1 | Watt Meter Report Period | If the setting is configured for 1hour (set value =720), the PAB01 will report its instant power consumption every 1 hour to the node of correspond Group. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). | 0 | 2 | 0 | 0 | 720 | | From | To | Description |
|---|
| 1 | 32767 | 5*720s=3600s=1 hour |
|
| 2 | KWH Meter Report Period | If the setting is configured for 1hour (set value =720), the PAB01 will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 45 hours (5s*32767/3600=45hr). | 0 | 2 | 0 | 0 | 720 | | From | To | Description |
|---|
| 1 | 32767 | 5*720s=3600s=1 hour |
|
| 3 | Selected Endpoint | If Controller can't use Multi_Channel command class to access the endpoint of PAB01, you may configure the endpoint value to react the Basic Command Class 、Binary Switch Command Class or Meter Command Class V3. | 0 | 1 | 0 | 0 | 3 | | From | To | Description |
|---|
| 1 | 1 | 1:CT1 | | 2 | 2 | 2:CT2 | | 3 | 3 | 3:CT1 and CT2 |
|
| 4 | Threshold of Current for Load Caution | This is a warning when the current of load over the preset threshold value, If the setting value is 6000, when the load wattage of CT1 or CT2 over 60A, PAB01 will send current Meter Report command to the node of correspond Group. | 0 | 2 | 0 | 0 | 6000 | | From | To | Description |
|---|
| 10 | 6000 | 6000*0.01A=60A |
|
| 5 | Threshold of KWh for Load Caution | This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of CT1 or CT2 over this value, PAB01 will send KWh Meter Report command to the node of correspond Guoup, minum value is 1KWh and default value is 10000 kWh. | 0 | 2 | 0 | 0 | 10000 | | From | To | Description |
|---|
| 1 | 10000 | 10000*1KWH=10000KWH |
|
| 6 | Existence of Endpoint3 | Multi-Channel Command is a good way to control relay1 and relay2 of PAB01 individually. The endpoint3 of PAB01 is related to both relay1 and relay2. In some condition it becomes redundant in Multi-Channel Command Class. When the Existence of Endpoint3 is set as 2, the endpoint3 will be disabled. The default value is 1. Endpoint1 and Endpoint2 are fixed, only Endpoint3 is dynamic. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 1 | 1 | 1 : Endpoint3 exist | | 2 | 2 | 2 : No Endpoint3 |
|