Product Recognition | |
|---|
Certification Number | ZC14-22030084 |
|---|
Name | Smart Energy Plug |
|---|
Short Description | PAN44 is a Smart Energy Plug.
The built-in power meter can let you monitor the power consumption of your electric appliances.
The product supports an Over the Air (OTA) feature for the products firmware upgrade. |
|---|
Long Description | PAN44 is a beautiful, innovative and good performance smart outlet. The built-in power meter can let you monitor the power consumption of your electric appliances. PAN38 is also a well-designed and remotely intelligent device. You can easily know the states of your home appliances like lamp or oven in your kitchen. And no need to worry about if they are not turned off. You can switch the lamp off or turn the oven off when you are in office or even go on a vacation.
The PAN44 smart outlet can work as a repeater in Z-Wave™ network. It can extend the Z-Wave™ network range. And no need to do any configuration, just plug it in the socket. |
|---|
Brand | Philio |
|---|
Product Identifier | PAN44_JP |
|---|
Product Line | Philio Z-Wave Products |
|---|
OEM Version | HW: 01 FW: 01.01 |
|---|
Hardware Platform | ZGM130S037HGN2 / ZGM130S037HGN1 |
|---|
Z-Wave Version | 7.16.3 |
|---|
Library Type | END_NODE_ENHANCED_232 |
|---|
Device Type | Binary Switch DT |
|---|
Role Type | ROLE_TYPE_SLAVE_ALWAYS_ON |
|---|
Manufacturer ID | 0x013C |
|---|
Product Type ID | 0x0001 |
|---|
Product ID | 0x0093 |
|---|
User Icon | 0x0700 |
|---|
Installer Icon | 0x0700 |
|---|
Frequency Plans | JP: 922.50MHz, 923.90MHz, 926.30MHz |
|---|
Categories | On/Off Switches/Devices |
|---|
Countries / Regions | Costa Rica, Japan |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_BASIC_V2 | Basic V2 | 0x20 | 2 | COMMAND_CLASS_SWITCH_BINARY_V2 | Binary Switch V2 | 0x25 | 2 | COMMAND_CLASS_CONFIGURATION_V4 | Configuration V4 | 0x70 | 4 | COMMAND_CLASS_METER_V5 | Meter V5 | 0x32 | 5 | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information (AGI) V3 | 0x59 | 3 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta Data V5 | 0x7A | 5 | COMMAND_CLASS_INDICATOR_V3 | Indicator V3 | 0x87 | 3 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_SECURITY | Security 0 | 0x98 | 1 | COMMAND_CLASS_SECURITY_2 | Security 2 | 0x9F | 1 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 |
|
|---|
S2 Classes | S2_AUTHENTICATED, S2_UNAUTHENTICATED |
|---|
Documents | Category | Description | File |
|---|
Manual_English | I had changed "SmartSart" to "SmartStart" and all "group 1" to "Lifeline Group" in this version( PAN44_MANU_20220322.pdf). | |
|
|---|
Features | Feature | Values |
|---|
Color | | Firmware Updatable | Value |
|---|
Updatable by Consumer by RF |
|
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Group Name | Profile |
|---|
1 | 5 | 0 | Lifeline | 0x0001 |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value |
|---|
1 | Watt Meter Report Period | If the setting is configured for 1hour (set value =720), the PAN38 will report its instant power consumption every 1 hour to the node of correspond Group. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). If the setting value is 0, the auto report function of meter Watt will be disabled. | 1 | 2 | 0 | 0 | 0x02D0 | 2 | KWH Meter Report Period | If the setting is configured for 1hour (set value =6), the PAN38 will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). If the setting value is 0, the auto report function of meter KWh will be disabled. | 1 | 2 | 0 | 0 | 0x0006 | 3 | Threshold of current for Load Caution | This is a warning when the current of load over the preset threshold value, if the setting value is 750, when the load current of Relay1 or Relay2 over this value, PAN38 will send current meter report to the node of correspond Group, the Range of the setting value is from 10 to 750, and the default value is 750. | 1 | 2 | 0 | 0 | 0x0514 | 4 | Threshold of KWh for Load Caution | This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 or Relay2 over this value, PAN38 will send KWh Meter Report command to the node of correspond Group, minimum value is 1KWh and default value is 10000 kWh. | 1 | 2 | 0 | 0 | 0x2710 | 5 | Restore switch state mode | Whenever the AC power return from lost, PAN38 will restore the switch state which could be SWITCH OFF、LAST SWITCH STATE、SWITCH ON. The default setting is LAST SWITCH STATE. | 2 | 1 | 0 | 0 | 0x01 | 6 | Mode of Switch Off function | When the mode of switch On/Off is set to 0, any command of switch off will be disabled and the Off function of include button will be disabled. The default setting is enable mode. When manual On/Off function is disabled, the RF command and include button can only switch On but not Off. This is useful function for keeping the device in switch on state. | 2 | 1 | 0 | 0 | 0x01 | 7 | LED indication mode | LED indication mode: The default setting is Show Switch State. 3-7-1 Show Switch State: When switch is on, LED is on. When switch is off, LED is off. 3-7-2 Show Night mode: When switch is on, LED is off. When switch is off, LED is on. 3-7-3 One Flash mode: When the state of switch changes, LED will be on only one second, then LED keeps off. | 2 | 1 | 0 | 0 | 0x01 | 8 | Watt differential report mode | Whenever Watt value of PAN38 changes over 5% of last reading value, it will send Meter report to the group 1 nodes. However, if Watt differential mode as 0, the unsolicited report will be disabled. | 2 | 1 | 0 | 0 | 0x01 | 9 | Switch status report mode | Whenever PAN38 manually switch on or off, it will send BINARY_SWITCH_ REPORT to the node of group1, disable when set to 0. | 2 | 1 | 0 | 0 | 0x01 |
|
|---|
Texts | ID | Description | Value |
|---|
8 | Where to find S2 DSK on product | 1. The product has a DSK string. Key in the first five digits to initiate the SmartStart process, or scan QR code.
2. SmartStart enabled products can be added into a Z-Wave™ network by scanning the Z-Wave™ QR Code on the product, with a controller providing SmartStart inclusion.No further action is required and the SmartStart product will be added automatically to the closest network within 10 minutes of being switched on. | 1 | Classic Inclusion | 1. Put your Z-Wave™ controller into inclusion mode by following the instructions provided by the controller manufacturer.
2. Press the on/off button three times within two seconds to enter inclusion mode. | 2 | Classic Exclusion | 1. Put your Z-Wave™ controller into exclusion mode by following the instructions provided by the controller manufacturer.
2. Press the on/off button three times within two seconds to enter exclusion mode.
3. Node ID will be excluded. | 5 | Factory Reset Procedure | 1. Press the on/off button three times within two seconds.
2. Within 1 second, press on/off button again last for 5 seconds.
3. Device has been reset. |
|
|---|
Supported / Controlled Meter Types | Meter Type | Rate Type |
|---|
Electric meter | Import (consumed) |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Power Management | (Refer to parameters): State idle | Power Management | Over-load status: Over-load detected |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Supports SmartStart | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|