Product Recognition | |
|---|
Certification Number | ZC12-22010330 |
|---|
Name | Smart Lock |
|---|
Short Description | This product can remotely lock and unlock the door and check the status by remote operation. |
|---|
Long Description | This product is an electronic door lock "FGT-0003" that supports Z-Wave Plus™ as standard. This is attached to the thumb turn and unlocked / locked using the controller. |
|---|
Brand | MITSUMI |
|---|
Product Identifier | FGT-0003 |
|---|
Product Line | "FGT-xxxx" Series |
|---|
OEM Version | HW: 1 FW: 7.14:00.09 |
|---|
Hardware Platform | ZGM130 |
|---|
Z-Wave Version | 7.14.3 |
|---|
Library Type | SLAVE_ENHANCED_232 |
|---|
Device Type | Lock |
|---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_LISTENING |
|---|
Manufacturer ID | 0x0112 |
|---|
Product Type ID | 0x0011 |
|---|
Product ID | 0x0001 |
|---|
User Icon | 0x0300 |
|---|
Installer Icon | 0x0300 |
|---|
Frequency Plans | JP: 922.50MHz, 923.90MHz, 926.30MHz |
|---|
Categories | Locks |
|---|
Countries / Regions | Japan |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_CONFIGURATION_V4 | Configuration V4 | 0x70 | 4 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information (AGI) V3 | 0x59 | 3 | COMMAND_CLASS_DOOR_LOCK_V4 | Door Lock V4 | | 0 | COMMAND_CLASS_INDICATOR_V3 | Indicator V3 | 0x87 | 3 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta Data V5 | 0x7A | 5 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_SECURITY_2 | Security 2 | 0x9F | 1 | COMMAND_CLASS_SECURITY | Security 0 | 0x98 | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_BASIC_V2 | Basic V2 | 0x20 | 2 | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 |
|
|---|
S2 Classes | S2_ACCESS_CONTROL |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product Manual in Japanese | | Manual_English | Product Manual in English | |
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Group Name | Description |
|---|
1 | 5 | 0 | Lifeline | Association Group 1 (Lifeline) |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
1 | Buzzer On/Off | Buzzer On/Off | 2 | 1 | 0 | 1 | 1 | From | To | Description |
|---|
0 | 1 | Buzzer disable/enable |
|
|
|---|
Texts | ID | Description | Value |
|---|
8 | Where to find S2 DSK on product | You can check the DSK code and QR code on the label by removing the Top cover of this product. | 1 | Classic Inclusion | 1. Set the controller in "Add (Inclusion)" mode.
(For the operation procedure, see the instruction manual of the controller.)
2. Press the lock operation switch once with a thin stick and release it immediately.
The registration operation starts with a single beeping sound.
3. The connection is complete when the LED blinks from blue to green.
Check the connection using the controller or a dedicated application. | 2 | Classic Exclusion | 1. Set the controller in "Remove (Exclusion)" mode.
2. Remove the top cover and press the lock operation switch once with a thin stick and release it immediately. The LED turns yellow once with a beeping sound.
3. The disconnection is complete when the LED blinks blue. Check the Exclusion using the controller or the dedicated application. | 4 | Wake-Up Procedure | Set the lock position and unlock position of the thumb turn knob.
■Insert the batteries
Remove the top cover, remove the battery holder, and insert four batteries.
Attach the battery holder with the battery inserted to the lock body. The LED flashes green with a confirmation sound. Leave the top cover removed.
* Be sure to use 4 batteries. Also, do not use batteries that are in use and new batteries together.
■Setting the thumb turn knob rotation direction
◇Start setting
Press and release the operation switch on the left side of the lock body with
a thin stick for 5 seconds or longer.
The LED will light up light blue once and long beep.
After that, the LED will blink light blue.
◇Unlocking position setting
Turn the thumb turn knob of this unit to the unlocked position.
Press and release the operation switch on the left side of the lock body with a thin stick for 5 seconds or longer.
The LED will red once and beep twice. After that, the LED will blink light blue.
◇Locking position setting
Turn the thumb turn knob of this unit to the locked position.
Press and release the operation switch on the left side of the lock body with a thin stick for 5 seconds or longer.
The LED will blue once and beep once. After that, the LED will blink light blue.
◇Positioning
With the thumb turn knob locked, use a thin stick to press and release the operation switch on the left side of the lock body for 5 seconds or longer.
The LED will light blue once and beep three times. | 5 | Factory Reset Procedure | Remove the top cover, press and release the operation switch on the left side of the lock body with a thin stick for 5 seconds or longer. The Factory Reset is complete when the LED blinks blue.
Please use this procedure only in the event that the primary controller is lost. All the settings and the controller information are cleared to return to the factory default. |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Is Flirs | Yes |
|---|
Supports SmartStart | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|