Product Recognition | |
|---|
Certification Number | ZC14-22110168 |
|---|
Name | Smart Noise Monitor (Sigma Nu) |
|---|
Short Description | Noise Monitor sensor that measures detected audio levels. Indoor Use Only. |
|---|
Long Description | Noise Monitor sensor that measures detected audio levels and sends notification messages over Z-Wave™ back to the controller. Indoor Use Only. |
|---|
Brand | Alarm.com |
|---|
Product Identifier | ADC-N10-N |
|---|
Product Line | Audio Sensor |
|---|
OEM Version | HW: 01 FW: 00.49:00.51 |
|---|
Hardware Platform | ZGM130S037HGN2 / ZGM130S037HGN1 |
|---|
Z-Wave Version | 7.17.2 |
|---|
Library Type | END_NODE_ENHANCED_232 |
|---|
Device Type | Multilevel Sensor DT |
|---|
Role Type | ROLE_TYPE_SLAVE_ALWAYS_ON |
|---|
Manufacturer ID | 0x0094 |
|---|
Product Type ID | 0x0001 |
|---|
Product ID | 0x0001 |
|---|
User Icon | 0x0D1E |
|---|
Installer Icon | 0x0D1E |
|---|
Frequency Plans | US: 916.00MHz, 908.40MHz, US_LR: 912.00MHz, 920.00MHz |
|---|
Categories | Sensors |
|---|
Countries / Regions | Canada, United States of America |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_CONFIGURATION_V4 | Configuration V4 | 0x70 | 4 | COMMAND_CLASS_SENSOR_MULTILEVEL_V11 | Multilevel Sensor V11 | 0x31 | 11 | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information (AGI) V3 | 0x59 | 3 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta Data V5 | 0x7A | 5 | COMMAND_CLASS_INDICATOR_V3 | Indicator V3 | 0x87 | 3 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_SECURITY_2 | Security 2 | 0x9F | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_SUPERVISION_V2 | Supervision V2 | 0x6C | 2 | COMMAND_CLASS_TIME_PARAMETERS | Time Parameters | 0x8B | 1 |
|
|---|
S2 Classes | S2_AUTHENTICATED, S2_UNAUTHENTICATED |
|---|
Documents | Category | File |
|---|
Manual_English | | Installer_Guide | | Adv_Manual | |
|
|---|
Features | Feature | Values |
|---|
Firmware Updatable | Value |
|---|
Updatable by Professional/Technician |
|
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Group Name | Profile |
|---|
1 | 4 | 0 | Lifeline | 0x0001 |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Read-only |
|---|
1 | OVRD_REPORT_PRD | See manual | 1 | 2 | 0 | 0 | 0x00b4 | | 2 | DB_READ_INTVL | See manual | 1 | 2 | 0 | 0 | 0x03e8 | | 3 | AGGR_TYPE | See manual | 2 | 1 | 0 | 0 | 0x04 | | 4 | DB_SUST_WIN | See manual | 1 | 2 | 0 | 0 | 0x000a | | 5 | EN_PRD_OVERRIDE | See manual | 1 | 1 | 0 | 0 | 0x00 | | 17 | MED_REPORT_PRD | See manual | 1 | 2 | 0 | 0 | 0x0708 | | 23 | HI_RANGE_WIDTH | See manual | 1 | 1 | 0 | 0 | 0x0a | | 24 | VHI_RANGE_WIDTH | See manual | 1 | 1 | 0 | 0 | 0x0b | | 64 | NTC_REPORT_PRD | See manual | 1 | 4 | 0 | 0 | 0x00000e10 | | 80 | RESET_DEVICE | See manual | 1 | 2 | 0 | 0 | 0x0000 | | 81 | RST_REASON_ZGM | See manual | 1 | 1 | 0 | 0 | 0x00 | Yes | 82 | RST_REASON_HOST | See manual | 1 | 1 | 0 | 0 | 0x00 | Yes |
|
|---|
Texts | ID | Description | Value |
|---|
8 | Where to find S2 DSK on product | The SmartStart DSK is located on the back label of the Noise Sensor device. | 1 | Classic Inclusion | 1.1 Adding the Noise Sensor to a Z-Wave network
1. Put Z-Wave controller into Add mode. See Z-Wave controller documentation for further information.
2. Press the pairing button on the side of the control unit. The LED will begin to blink green.
3. The unit has been successfully added to the network when the LED becomes solid green. | 2 | Classic Exclusion | 1.2 Removing the Noise Sensor from a Z-Wave network
1. Put Z-Wave controller into Remove mode. See Z-Wave controller documentation for further documentation.
2. Press the pairing button on the side of the control unit. The LED will begin to blink green.
3. The unit has been successfully removed from the network when the LED turns off. | 5 | Factory Reset Procedure | 1. Press and hold the pairing button on the side of the control unit 15 seconds. The LED will then alternate red and green until the button is released, at which point the reset process will begin.
2. The device will first send a Device Reset Locally notification, which notifies the controller that it should be removed from the Z-Wave network
3. Once the device has been reset, the LEDs will return to their normal state.
4. Device reset will reset NVM, EEPROM, and the Z-Wave chip. |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
System | HW status: System hardware failure (manufacturer proprietary failure code provided) | System | Heartbeat | System | SW status: System software failure (manufacturer proprietary failure code provided) | Power Management | Power status: Power has been applied | Power Management | Mains status: AC mains disconnected |
|
|---|
Supported Multilevel Sensors | Multilevel Sensor Type |
|---|
Loudness | Target temperature |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Supports SmartStart | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|
Radio Range Z-Wave LR (m) | 400 |
|---|