| 24 | Notification when Load status change | Smart Plug can send notifications to association device (Group Lifeline) when state of smart plug’s load change. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 0 | 0 | The function is disabled | | 1 | 1 | Send Basic report | | 2 | 2 | Send Basic report only when Load condition is not changed by Z-WAVE Command |
|
| 151 | Threshold of change in wattage | Power threshold to be interpreted, when the change value of load power exceeds the setting threshold, the smart plug will send meter report to associated device (Group Lifeline). | 0 | 2 | 0 | 0 | 50 | | From | To | Description |
|---|
| 0 | 0 | The function is disabled. | | 1 | 65535 | The minimum change value in wattage for sending a meter report to the associated device |
|
| 152 | Threshold of change in wattage percentage | Power percentage threshold to be interpreted, when change value of the load power exceeds the setting threshold, the smart plug will send meter report to associated device (Group Lifeline). | 0 | 1 | 0 | 0 | 10 | | From | To | Description |
|---|
| 0 | 0 | The function is disabled. | | 1 | 255 | The minimum change value in wattage percent for sending a meter report to the associated device |
|
| 172 | Intervals of sending METER REPORT (for kWh) | The interval of sending meter report(in term of kWh) to associated device (Group Lifeline). | 0 | 4 | 0 | 0 | 300 | | From | To | Description |
|---|
| 0 | 0 | The function is disabled. | | 5 | 2678400 | The time for sending a meter report |
|
| 173 | Intervals of sending METER REPORT (for voltage). | The interval of sending meter report(in term of voltage) to associated device (Group Lifeline). | 0 | 4 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | The function is disabled | | 5 | 2678400 | The time for sending a meter report |
|
| 174 | Intervals of sending METER REPORT (for current). | The interval of sending meter report(in term of current) to associated device (Group Lifeline). | 0 | 4 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | The function is disabled. | | 5 | 2678400 | The time for sending a meter report |
|