Product Recognition | |
|---|
Certification Number | ZC10-18076197 |
|---|
Name | Smart Temperature & Humidity Sensor |
|---|
Short Description | The smart humidity and temperature sensor adopts Z-Wave protocol. It is used to detect humidity and temperature. When the humidity or temperature exceeds the alarm thresholds, it will send alarm notifications to gateway immediately. |
|---|
Long Description | The smart humidity and temperature sensor adopts Z-Wave protocol. It is used to detect humidity and temperature. When the humidity or temperature exceeds the alarm thresholds, it will send alarm notifications to gateway immediately. |
|---|
Brand | HEIMAN |
|---|
Product Identifier | HS1HT-Z |
|---|
OEM Version | HW: 255 FW: 3.01 |
|---|
Hardware Platform | ZM5202 |
|---|
Z-Wave Version | 6.71.03 |
|---|
Library Type | SLAVE_ROUTING |
|---|
Device Type | Notification Sensor |
|---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_REPORTING |
|---|
Manufacturer ID | 0x0260 |
|---|
Product Type ID | 0x8007 |
|---|
Product ID | 0x1000 |
|---|
User Icon | 0x0DFF |
|---|
Installer Icon | 0x0DFF |
|---|
Frequency Plans | EU: 869.85MHz, 868.40MHz |
|---|
Categories | Sensors, Security Add-Ons |
|---|
Countries / Regions | European Union |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi-Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_SENSOR_MULTILEVEL_V10 | Sensor Multilevel V10 | 0x31 | 10 | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 |
|
|---|
S2 Classes | S2_UNAUTHENTICATED |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Battery Quantity | | Battery Type | | Color | | Sensors | Value |
|---|
Air Temperature | Humidity |
|
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
1 | 5 | 0 | Z-Wave Plus Lifeline |
|
|---|
Texts | ID | Description | Value |
|---|
4 | Device Wake-Up | Wake up Notification is transmitted every 300 seconds by default. | 1 | Inclusion | - Click [Add] icon in Z-Wave Controller.
- Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.
- If Inclusion Process is successful, Green LED will turn off. | 2 | Exclusion | - Click [Remove] icon in Z-Wave Controller.
- Press the Net_Button 3 times within 1.5s
- If Exclusion Process is successful, Green LED is Blinking 6 times, then turn off | 5 | Factory Reset | -Long press Net_Button at least 10 seconds in the product.
- Device Reset Locally notification is Transmitted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable. |
|
|---|
Supported Multilevel Sensors | Multilevel Sensor Type |
|---|
Air temperature | Humidity |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|