Product Recognition | |
|---|
Certification Number | ZC10-17115877 |
|---|
Name | Smart Water Leakage Sensor |
|---|
Short Description | Highly sensitive flood sensor with a bracket for easy installation. |
|---|
Long Description | Highly sensitive flood sensor keeping your home safe from any kind of water leakage or overflow. Separate design of body and sensor prevents the influence resulted from high humidity. |
|---|
Brand | Zipato |
|---|
Product Identifier | hm-hs1wl-z.eu |
|---|
OEM Version | HW: 14 FW: 2.00 |
|---|
Hardware Platform | ZM5202 |
|---|
Z-Wave Version | 6.51.09 |
|---|
Library Type | SLAVE_ROUTING |
|---|
Device Type | Notification Sensor |
|---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_REPORTING |
|---|
Manufacturer ID | 0x0131 |
|---|
Product Type ID | 0x8004 |
|---|
Product ID | 0x1000 |
|---|
User Icon | 0x0C05 |
|---|
Installer Icon | 0x0C05 |
|---|
Frequency Plans | EU: 869.85MHz, 868.40MHz |
|---|
Categories | Sensors |
|---|
Countries / Regions | European Union |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_NOTIFICATION_V7 | Notification V7 | 0x71 | 7 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_SENSOR_BINARY_V2 | Sensor Binary V2 | 0x30 | 2 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 |
|
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Battery Quantity | | Battery Type | | Supported Notification Types | |
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
4 | 5 | 0 | Association group 4: Root Device group(Notification) Maximum supported nodes are 5. 1-Notification reports reports status of detect water or no water via Lifeline. 2-When the sensor detects status change between water and no water, the device will be triggered. | 5 | 5 | 0 | Association group 5: Root Device group(Notification) Maximum supported nodes are 5. 1-Binary Sensor reports the removed status of water sensor. 2- When the sensor detects status change of tamper, the device will be triggered. | 1 | 1 | 0 | Association group 1: Lifeline association group - Maximum supported node is 1. Include command classes: Battery report, Notification report, and Device Reset Locally notification, Binary report. | 2 | 5 | 0 | Association group 2: Root Device group(Binary Sensor) Maximum supported nodes are 5. Binary Sensor Command Class: Compatible with 300 series 1- Binary Sensor reports status of water or no water via Lifeline. 2- When the sensor detects status change between water and no water, the device will be triggered. | 3 | 5 | 0 | Association group 3: Root Device group(Binary Sensor) Maximum supported nodes are 5. Binary Sensor Command Class:Compatible with 300 series 1-Binary Sensor reports the removed status of water sensor. 2-When the sensor detects status change of tamper, the device will be triggered. |
|
|---|
Texts | ID | Description | Value |
|---|
1 | Inclusion | - Press the Func_Buttom 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.
- If Inclusion Process is successful, Green led will turn off. | 2 | Exclusion | - Press the Func_Buttom 3 times within 1.5s
- If Exclusion Process is successful, Green led is Blinking 6 times, then turn off. | 5 | Factory Reset | - Long press Func_Buttom while installing batteries in the product.
- Device Reset Locally notification is Transmitted.
- Use the reset procedure only when the primary controller is missing or inoperable. | 4 | Device Wake-Up | - Wake up Notification is transmitted every 24 hours by default.
- Wake up Notification is transmitted after Notification Report is Transmitted |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Water Alarm | (Refer to parameters): State idle |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|