Product Recognition | |
|---|
Certification Number | ZC10-19076620 |
|---|
Name | SmartThinQ(Standard) Hub 2.0 |
|---|
Short Description | LG IoT Hub with SmartThinQ |
|---|
Long Description | The LG IoT Hub can be controlled with a limited set of products made with the standard Z-Wave Plus standard.
Compatible with Door sensor, Smoke sensor, CO sensor, Temperature sensor, Humidity sensor, Motion sensor, Door / window sensor, On / off switch, On / off switch, Dimmable bulb, Dimmable switch, Dimmable outlet, Color Dimmable bulb , Door locks, valves, thermostats and multi-sensors.
With SmartThinQ app, you can enjoy more convenient smart life anytime, anywhere. |
|---|
Brand | LG Electronics |
|---|
Product Identifier | IGC73W |
|---|
OEM Version | HW: 1 FW: 5.50:02.61:01.00:01.00 |
|---|
Hardware Platform | ZM5101 |
|---|
Z-Wave Version | 6.71.03 |
|---|
Library Type | CONTROLLER_BRIDGE |
|---|
Device Type | Central Controller |
|---|
Role Type | ROLE_TYPE_CONTROLLER_CENTRAL_STATIC |
|---|
Manufacturer ID | 0x015B |
|---|
Product Type ID | 0x0bb9 |
|---|
Product ID | 0x0bb9 |
|---|
User Icon | 0x0500 |
|---|
Installer Icon | 0x0500 |
|---|
Frequency Plans | KR: 920.90MHz, 921.70MHz, 923.10MHz |
|---|
Categories | All Controllers, Gateway Controller |
|---|
Countries / Regions | Republic of Korea |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_NETWORK_MANAGEMENT_INSTALLATION_MAINTENANCE | Network Management Installation and Maintenance | 0x67 | 1 | COMMAND_CLASS_INCLUSION_CONTROLLER | Inclusion Controller | 0x74 | 1 | COMMAND_CLASS_NETWORK_MANAGEMENT_INCLUSION_VERSION_2 | Network Management Inclusion V2 | 0x34 | 0 | COMMAND_CLASS_APPLICATION_STATUS | Application Status | 0x22 | 1 | COMMAND_CLASS_CRC_16_ENCAP | CRC16 Encapsulation | 0x56 | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta-Data V5 | 0x7A | 5 | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information V3 | 0x59 | 3 | COMMAND_CLASS_NETWORK_MANAGEMENT_PROXY_V2 | Network Management Proxy V2 | 0x52 | 2 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_NETWORK_MANAGEMENT_BASIC_V2 | Network Management Basic V2 | 0x4D | 2 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_MULTI_CMD | Multi-Command | 0x8F | 1 |
|
|---|
Controlled Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_NOTIFICATION_V7 | Notification V7 | 0x71 | 7 | COMMAND_CLASS_SWITCH_BINARY_V2 | Switch Binary V2 | 0x25 | 2 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_THERMOSTAT_FAN_MODE_V4 | Thermostat Fan Mode V4 | 0x44 | 4 | COMMAND_CLASS_USER_CODE | User Code | 0x63 | 1 | COMMAND_CLASS_NETWORK_MANAGEMENT_INCLUSION_VERSION_2 | Network Management Inclusion V2 | 0x34 | 0 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi-Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_APPLICATION_STATUS | Application Status | 0x22 | 1 | COMMAND_CLASS_THERMOSTAT_OPERATING_STATE | Thermostat Operating State | 0x42 | 1 | COMMAND_CLASS_THERMOSTAT_MODE | Thermostat Mode | 0x40 | 1 | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | COMMAND_CLASS_INDICATOR | Indicator | 0x87 | 1 | COMMAND_CLASS_CRC_16_ENCAP | CRC16 Encapsulation | 0x56 | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_SENSOR_BINARY_V2 | Sensor Binary V2 | 0x30 | 2 | COMMAND_CLASS_THERMOSTAT_FAN_STATE_V2 | Thermostat Fan State V2 | 0x45 | 2 | COMMAND_CLASS_THERMOSTAT_SETPOINT_V3 | Thermostat Setpoint V3 | 0x43 | 3 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_BARRIER_OPERATOR | Barrier Operator | 0x66 | 1 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_METER_V3 | Meter V3 | 0x32 | 3 | COMMAND_CLASS_SENSOR_MULTILEVEL_V9 | Sensor Multilevel V9 | 0x31 | 9 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta-Data V5 | 0x7A | 5 | COMMAND_CLASS_MULTI_CHANNEL_V4 | Multi-Channel V4 | 0x60 | 4 | COMMAND_CLASS_SWITCH_MULTILEVEL_V4 | Switch Multilevel V4 | 0x26 | 4 | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information V3 | 0x59 | 3 | COMMAND_CLASS_NETWORK_MANAGEMENT_PROXY_V2 | Network Management Proxy V2 | 0x52 | 2 | COMMAND_CLASS_BASIC_V2 | Basic V2 | 0x20 | 2 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_DOOR_LOCK_V3 | Door Lock V3 | 0x62 | 3 | COMMAND_CLASS_NETWORK_MANAGEMENT_BASIC_V2 | Network Management Basic V2 | 0x4D | 2 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_MULTI_CMD | Multi-Command | 0x8F | 1 |
|
|---|
S2 Classes | S2_UNAUTHENTICATED, S2_AUTHENTICATED, S2_ACCESS_CONTROL |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Communications Connections | Value |
|---|
Ethernet (Wired) | Ethernet (Wireless/WiFi) |
| Firmware Updatable | Value |
|---|
Updatable by Manufacturer |
| Color | | Communications Protocol | | Gateway Has Preferred Partners | | Supported Meter Type | | Sensors | Value |
|---|
Air Temperature | Humidity |
| Supported Notification Types | Value |
|---|
Smoke Alarm | CO Alarm | Water Alarm |
|
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
1 | 5 | 0 | Z-Wave Plus Lifeline |
|
|---|
Texts | ID | Description | Value |
|---|
23 | Controller Inclusion | How to Include Z-Wave devices in SmartThinQ Application :
You must register the LG IoT Hub in your app, and then you can include the Z-Wave devices to that LG IoT Hub and send control commands.
-Include Normal Device
When you enter the detailed screen of LG IoT Hub, there is no device included as the message ""Link to device registration"" appears at the center of the screen.
You can select the link to enter the device registration screen or select the + button on the upper right.
LG affiliate sensors can register the device after selecting the device type.
However, since Z-Wave can register any type of device when registering the device, so scroll down from the device registration screen and select ""Other devices"".
Select “Start Search”, you will enter Z-Wave inclusion mode.
If the third LED of LG IoT Hub is blinking, controller will actually send a Z-Wave inclusion frame.
Register the actual device.
After registering the device, for some device types, you will be prompted to select the device type.
When registering the BinarySwitch, the user is forced to recognize whether the device is Plug type, Switch type or Bulb type.
Also, in case of sensor, the user selects the type when registering the device.
When the registration is completed, the registered device will shown.
- Include S2 SSA Device
When registering the S2 SSA device, a screen for entering the QR code or pin code appears during device registration.
-Include S2 SSA Device
When registering the S2 SSA device, a screen for entering the QR code or pin code appears during device registration.
-Include S2 CSA Device
When registering the S2 CSA device, a popup for asking client side authentication request appears during device registration.
If the Secure device is included insecurely or if controller cannot get a sleep device wakeup interval properly, an abnormal registration notification pop-up will appear.
The corresponding device can not enter the detailed screen, and an error
pop-up occurs when selecting.
-Include Multi-endpoint Devices
Multi-endpoint devices or devices that support multiple sensor types are called ""multi-devices"", and when they enter the detailed screen of the device, it shows which device types are supported.
When the endpoint device type of the multi-device is unknown, only ""IoT device"" is displayed as below screen when entering the detailed screen. The user can directly choose the endpoint device type by selecting the corresponding endpoint device.
-Include Unsupported Device
If you register a device that is not supported by our LG IoT Hub, the device will not appear on the screen. | 3 | Learn Mode (adding another controller) | -How to Access
Power on Gateway and wait 2~3 minutes to get ready.
To access the web page, you first need to find the pin code of the gateway using the mobile phone app. Please refer “App usage guide” document how to get the pin code.
After getting the pin code of the gateway, press the gateway ENT(with any pin) 5 times, the third LED will blink.
If the third LED is not blinking, press the button again.
With web browser (Chrome browser is recommended), connect to Z-Wave Expert Page (http://ip_address:50001/zwavecert/login).
Input the Gateway pin code, and press Login button.
-setLearnMode
Select ‘setLearnMode’ in [Command List]
Click “Send Command” button.
Our controller supports S2 security, so if we include our controller into another controller (support S2 security), dsk popup will pop up.
Input our dsk code (5 digits) in primary controller.
Wait while pressing the “Update Log List” button until {""report"":""setLearnModeStart"",""info"":{""result"":""Success""}} appears in the log. This means setLearnMode start, and our controller gets the information about primary controller.
Wait while pressing the “Update Log List” button until {""report"":""setLearnModeReport"",""info"":{""result"":""Success""}} appears in the log. It takes a long time to send and receive information about controller and virtual node.
After success setLearnMode, our controller start “networkUpdate” to get the correct information about primary controller, so {""report"":""networkUpdateStart"",""info"":{""result"":""Success""}} and {""report"":""networkUpdateReport"",""info"":{""result"":""Success""}} will appears in the log.
Also, wait while pressing the “Update Log List” button until {""report"":""addDeviceReport"",""info"":{""result"":""Success"",""ThingUID"":""lgzwave:01""}} appears in the log.
“01” Node means primary controller’s node id.
Keep in mind that you have to wait long enough for the above log to come out.
If {""report"":"" setLearnModeReport "",""info"":{""result"":""Fail""}} appears in the log, then factory reset the controller, and try again.
If you want to send command to primary controller, please refer [Node] section. | 5 | Factory Reset | If the corresponding LG IoT Hub is registered in only one account, you can initialize the LG IoT Hub by selecting the previously registered LG IoT Hub on the remove screen.
Only the LG IoT Hub will be factory reset and the devices will still have information on the controller, so be careful when selecting the items below.
When LG IoT Hub is selected, all three LEDs of the LG IoT Hub will blink. When the factory reset is completed, the first and second LEDs will be turned on again.
If it not work, then press and hold the gateway ENT button for 10 seconds or more.
Note:
If this controller is the primary controller for your network, resetting it will result in the nodes in your network being orphaned and it will be necessary after the reset to exclude and re-include all of the nodes in the network. | 24 | Controller Exclusion | -How to Exclude Z-Wave devices in SmartThinQ Application :
In the LG IoT Hub detail screen, select the setting menu on the upper right.
If you select ""Remove"", ""Remove and initialize Z-Wave Device"" appears at the bottom with registered device list. Select the corresponding item.
a pop up prompting you to press the remove button on the device side, and when you press the device button, the message ""One product has been Removed. Do you want to continue? ""Pops up.
At this time, if you select OK, you can continue to remove other device.
You must select cancel to stop the remove operation. |
|
|---|
Supported / Controlled Meter Types | Meter Type | Rate Type | Description |
|---|
Electric meter | Import | Electric Meter Consumption |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|