| Product Recognition | |
|---|
| Certification Number | ZC10-16075133 |
|---|
| Name | SSR 302 (Dual Channel On/Off Power switch) |
|---|
| Short Description | The SSR 302 is a 2-channel relay/switch, it forms part of central heating and hot water control system, it can be operated by any third party controllers/Thermostat using ‘Binary Switch CC’ commands. |
|---|
| Long Description | The SSR 302 is a 2-channel relay/switch, it forms part of central heating and hot water control system, it can be operated by any third party controllers/Thermostat using ‘Binary Switch CC’ commands.
SSR 302 will act as a repeater once added into the Z-Wave network, providing an alternative communication route for units which otherwise would not be within communication distance of each other.
SSR 302 has a fail-safe mode where by the relay is turned OFF if another 'Thermostat Mode SET' command has not been received within 60 minutes. |
|---|
| Brand | Secure Controls (UK) |
|---|
| Product Identifier | MAX10Z-382 |
|---|
| OEM Version | HW: 1 FW: 2.1 |
|---|
| Hardware Platform | ZM5202 |
|---|
| Z-Wave Version | 6.51.06 |
|---|
| Library Type | SLAVE_ROUTING |
|---|
| Device Type | On/Off Power Switch |
|---|
| Role Type | ROLE_TYPE_SLAVE_ALWAYS_ON |
|---|
| Manufacturer ID | 0x0059 |
|---|
| Product Type ID | 0x0003 |
|---|
| Product ID | 0x0006 |
|---|
| User Icon | 0x0700 |
|---|
| Installer Icon | 0x0700 |
|---|
| Frequency Plans | EU: 869.85MHz, 868.40MHz |
|---|
| Categories | Thermostats, On/Off Switches/Devices, HVAC |
|---|
| Countries / Regions | European Union |
|---|
| Documents | |
|---|
| Features | | Feature | Values |
|---|
| Color | | | Neutral Wire Required | | | Electric Load Type | | Value |
|---|
| Inductive (e.g. Motor) |
| | IP (Ingress Protection) Rated | | | Switch Load Capacity Current | | | Loads Controlled | |
|
|---|
| Association Groups | | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
| 1 | 4 | 0 | Z-Wave Plus Lifeline,
SSR 302 will send unsolicited 'Binary Switch Report' to lifeline group whenever its relay status change. |
|
|---|
| Texts | | ID | Description | Value |
|---|
| 5 | Factory Reset | ""Please use this procedure only when the primary controller is missing or otherwise inoperable.""
Follow ‘Exclusion’ steps. | | 6 | Additional Special Features | SSR 302 has a fail-safe mode where by the relay is turned OFF if another 'Thermostat Mode SET' command has not been received within 60 minutes. | | 1 | Inclusion | STEP 1: Ensure the LED is flashing RED on the SSR 302, if not follow the ‘Exclusion’ steps first.
STEP 2: Put the 3rd party controller into inclusion mode.
STEP 3: Press and hold both white buttons on the SSR 302 until the LED starts flashing green.
The SSR 302 has been added onto the network and the LED will go solid amber.
NOTE: If the LED does not go solid amber then the add process has been unsuccessful. | | 2 | Exclusion | STEP 1: Put the 3rd party controller into exclusion mode.
STEP 2: Press and hold the two white buttons on the SSR 302.
The SSR 302 has been removed from the network when the LED starts flashing red.
NOTE: If the LED does not flash red then the remove process has been unsuccessful. |
|
|---|
| Supports NWI | Yes |
|---|
| Supports Explorer Frames | Yes |
|---|