Product Recognition | |
|---|
Certification Number | ZC10-18046093 |
|---|
Name | Standalone Relay 1-Pole |
|---|
Short Description | Z-Wave controllable Standalone 1-Pole Relay (3000W) designed to be concealed in wall boxes. |
|---|
Long Description | The Standalone 1-Pole Relay is exclusively Z-Wave controllable, and designed to handle loads up to 3000W and be concealed inside Wall Boxes. The Relay can be used to switch both Heat Sources and Light fixtures. The product also contains a fail-safe mechanism which will switch the relay ON and OFF at fixed intervals, in case communication from a controlling device is lost.
The Relay measures the immediate and accumulated power consumption of an attached load, which is reported at fixed intervals. |
|---|
Brand | SE Devices |
|---|
Product Identifier | AR1P |
|---|
OEM Version | HW: 30 FW: 3.00:03.00 |
|---|
Hardware Platform | ZM5202 |
|---|
Z-Wave Version | 6.71.01 |
|---|
Library Type | SLAVE_ENHANCED_232 |
|---|
Device Type | On/Off Power Switch |
|---|
Role Type | ROLE_TYPE_SLAVE_ALWAYS_ON |
|---|
Manufacturer ID | 0x024F |
|---|
Product Type ID | 0x0003 |
|---|
Product ID | 0x1013 |
|---|
User Icon | 0x0700 |
|---|
Installer Icon | 0x0700 |
|---|
Frequency Plans | EU: 869.85MHz, 868.40MHz |
|---|
Categories | All Lighting Devices, On/Off Switches/Devices |
|---|
Countries / Regions | European Union |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 | Firmware Update Meta-Data V4 | 0x7A | 4 | COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | Sensor Multilevel V5 | 0x31 | 5 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi-Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_SWITCH_BINARY | Switch Binary | 0x25 | 1 | COMMAND_CLASS_BASIC | Basic | 0x20 | 1 | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_METER_V2 | Meter V2 | 0x32 | 2 |
|
|---|
Controlled Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_BASIC | Basic | 0x20 | 1 |
|
|---|
S2 Classes | S2_UNAUTHENTICATED |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Switch Load Capacity Watts | | Neutral Wire Required | | Electric Load Type | Value |
|---|
Incandescent | Fluorescent | MLV (Magnetic) | LED | Inductive (e.g. Motor) |
| Firmware Updatable | Value |
|---|
Updatable by Professional/Technician |
| Switch Load Capacity Current | | Supported Meter Type | | Sensors | |
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
2 | 5 | 0 | Associated devices will be controlled according to local state changes. Supports Multichannel Association in addition to standard association.
Command Issued: Basic Set | 1 | 5 | 0 | The Lifeline group where all Root Device events are reported. All unsolicited Reports for the supported command classes will be issued to this group. Supports both normal and Multichannel Association.
Commands Issued:
- Sensor Multilevel Report - Reports Power Consumption and Temperatures
- Meter - Reports power consumption to the Controller every 15 minutes.
- Device Reset Locally – Reports factory resets to the Controller |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
4 | Safety Activate Delay | Safety Mode is activated after the configured number of seconds has elapsed. It will start by turning OFF the Back Unit when activated. A 0 value Disables Safety Mode. The MAX limit is 32767 seconds (9 hours, 6 minutes and 7 seconds) | 0 | 2 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 32767 | Safety Activation Delay |
| 5 | Safety OFF Period | The number of seconds to stay in OFF mode when Safety is activated. The Back unit turns ON when the timer have elapsed. If value is 0, the Back Unit will not turn back ON. The MAX limit is 32767 seconds (9 hours, 6 minutes and 7 seconds) | 0 | 2 | 0 | 0 | 600 | From | To | Description |
|---|
0 | 32767 | Safety OFF Period |
| 6 | Safety ON Period | The number of seconds to stay in ON mode when Safety is activated. The Back Unit turns back OFF when the timer have elapsed (and continues to turn ON and OFF alternately). If value is 0, the Back Unit WILL NOT turn ON at all. The MAX limit is 32767 seconds (9 hours, 6 minutes and 7 seconds) | 0 | 2 | 0 | 0 | 300 | From | To | Description |
|---|
0 | 32767 | Safety ON Period |
|
|
|---|
Texts | ID | Description | Value |
|---|
5 | Factory Reset | WARNING! Executing a Factory Reset on a device may make it stop working as wanted and WILL remove it from the Z-Wave network. Please DO NOT execute this procedure unless it’s absolutely necessary.
Press and Hold the Add/Remove button for about 15 seconds - until LED indicator starts blinking. Then release the button. The device will now be factory reset and removed from the Z-Wave network.
The button is located about 10 mm down in the middle of the three holes on the front. A thin tool (a very small screwdriver, a toothpick, a paper clip or similar) is needed to access the button. | 1 | Inclusion | To add the device to a Z-Wave network, the Z-Wave Controller must first be set into Add (Learn) mode. Then use a paperclip or a small pointy tool to push and hold the button in the button hole for approximately a second. The device LED will blink twice to indicate that it sends information to the Controller. | 2 | Exclusion | To remove the device from a Z-Wave network, the Z-Wave Controller must first be set into Remove (Learn) mode. Then use a paperclip or a small pointy tool to push and hold the button in the button hole for approximately a second. The device LED will blink twice to indicate that it sends information to the Controller. |
|
|---|
Supported / Controlled Meter Types | Meter Type | Rate Type | Description |
|---|
Electric meter | Import | Electric Meter Consumption |
|
|---|
Supported Multilevel Sensors | Multilevel Sensor Type |
|---|
Power | Voltage | Current |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|