Product Recognition | |
|---|
Certification Number | ZC10-17105800 |
|---|
Name | Thermostat Control Panel |
|---|
Short Description | The product is a Z-Wave enabled room thermostat
support control cool/heat/fan climate in Z-Wave
system. The desired temperature in the room can be
set locally using the button on the front of the unit. |
|---|
Long Description | The product is a Z-Wave enabled room thermostat
support control cool/heat/fan climate in Z-Wave
system. The desired temperature in the room can be
set locally using the button on the front of the unit. It
works in the same way as a normal room thermostat
with hard wired to the heating source; meanwhile
control is achieved using Z-Wave wireless signals
also. This enables you to control heating times and
schedule zone heating.
This product can be operated in any Z-Wave network
with other Z-Wave certified devices from other
manufacturers. All non-battery operated nodes within
the network will act as repeaters regardless of vendor
to increase reliability of the network. |
|---|
Brand | Jintaobao |
|---|
Product Identifier | JTB-3005-03 |
|---|
OEM Version | HW: 33 FW: 1.01:01.01 |
|---|
Hardware Platform | ZM5202 |
|---|
Z-Wave Version | 6.51.09 |
|---|
Library Type | SLAVE_ENHANCED_232 |
|---|
Device Type | Thermostat - HVAC |
|---|
Role Type | ROLE_TYPE_SLAVE_ALWAYS_ON |
|---|
Manufacturer ID | 0x015A |
|---|
Product Type ID | 0x3005 |
|---|
Product ID | 0x0003 |
|---|
User Icon | 0x1200 |
|---|
Installer Icon | 0x1200 |
|---|
Frequency Plans | EU: 869.85MHz, 868.40MHz |
|---|
Categories | Thermostats |
|---|
Countries / Regions | European Union |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | Sensor Multilevel V5 | 0x31 | 5 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_BASIC | Basic | 0x20 | 1 | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | COMMAND_CLASS_THERMOSTAT_FAN_MODE_V3 | Thermostat Fan Mode V3 | 0x44 | 3 | COMMAND_CLASS_THERMOSTAT_MODE_V2 | Thermostat Mode V2 | 0x40 | 2 | COMMAND_CLASS_THERMOSTAT_SETPOINT_V2 | Thermostat Setpoint V2 | 0x43 | 2 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 | Firmware Update Meta-Data V2 | 0x7A | 2 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 |
|
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Firmware Updatable | Value |
|---|
Updatable by Consumer by RF |
| Switch Load Capacity Current | | Switch Load Capacity Volt-Ampere | | Switch Load Capacity Watts | | Neutral Wire Required | | Sensors | | Thermostat HVAC Systems Supported | Value |
|---|
Simple Relay | Heat Only | Cool Only | Single Stage |
| Thermostat Modes | Value |
|---|
Heat | Cool | Resume | Fan Only | Energy Save Heat | Energy Save Cool |
| Thermostat Power Source | Value |
|---|
Mains powered (120V/240V) |
|
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
1 | 1 | 0 | Z-Wave Plus Lifeline, is assigned to send thermostat lifeline status to associated devices, including send the multilevel sensor report frame
of room temperature, and thermostat mode, fan speed, thermostat state etc. Please note that, external thermostat status is refresh one minute after change by manual locally. |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
1 | Synchronization Cool and Heat temperature set-point | Synchronization Cool and Heat temperature set-point while one of it has been change by master controller. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
-128 | -128 | Synchronization | 0 | 0 | No Synchronization |
| 2 | Inner master MCU communication address | Should setting same as inner master MCU configuration. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
1 | 127 | Should same as inner master MCU configuration. |
|
|
|---|
Texts | ID | Description | Value |
|---|
5 | Factory Reset | Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Press and hold PB button located on the back side of thermostat
panel for 10 seconds retrieve thermostat panel factory default. | 1 | Inclusion | Start master controller add device mode as instruction, press 3 time of PB button located on the back side of thermostat panel in 1.5 second,
LED flash indicator inclusion processing until included or 60 second timeout no detect any master controller. | 2 | Exclusion | Start master controller remove device mode as instruction, press 3 time of PB button located on the back side of thermostat panel in 1.5 second, LED flash indicator exclusion processing until excluded or 5 second timeout no detect any master controller. |
|
|---|
Supported Multilevel Sensors | Multilevel Sensor Type |
|---|
Air temperature |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|