| 3 | ECO Mode | this configuration setting displays if the thermostat is currently operating in ECO Mode. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | Off | | 1 | 1 | On |
|
| 4 | Thermostat Default Settings | This configuration setting controls factory reset of the physical device. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 1 | 1 | Restore Thermostat Factory Settings (minus z-wave) | | 0 | 0 | No Change |
|
| 5 | Temperature Calibration | Your thermostat was accurately calibrated at the factory, however, you can change the display temperature to match that of a previous thermostat, or to match another thermostat already in your home. The range of change is from -5F to 5F. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 5 | 0 - 5F; 0-2.8C | | 251 | 255 | (-5)-(-1)F; (-1) - (-2.8)C |
|
| 6 | LED Dimming (If applicable) | This configuration setting controls brightness of the LED display in the thermostat. | 0 | 1 | 0 | 0 | 3 | | From | To | Description |
|---|
| 0 | 0 | Low | | 1 | 1 | Medium | | 2 | 2 | High | | 3 | 3 | Auto |
|
| 7 | Demand Response Mode | This configuration setting controls the LED indicator light to signify the thermostat setpoint is part of a utility-set Demand Response Event. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 1 | 1 | On | | 0 | 0 | Off |
|
| 8 | Swing Setting | This configuration setting allows the user to control at what setpoint variance the HVAC system turns on at. The thermostat swing temperature is in units of 1 degrees Fahrenheit. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 0 | 10 | 0 - 10F; 0 - 5.6C | | 0 | 0 | |
|
| 9 | Differential Setting | The Differential is the number of degrees between the room temperature and the target temperature at which the 2nd stage will engage to bring the room temperature back to the target. The default is 3F. The programmable range is 0-10F. | 0 | 1 | 0 | 0 | 3 | | From | To | Description |
|---|
| 0 | 10 | 0 - 10F; 0 - 5.6C |
|
| 10 | OTA (Over The Air) programming error code | This configuration setting gives feedback on the status of an OTA programming update. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 2 | 2 | OTA cancelled before completion | | 3 | 3 | Fragment CRC error | | 4 | 4 | Total image CRC error | | 5 | 5 | External flash error | | 6 | 6 | Fragment received out of order | | 7 | 7 | Invalid firmware or manufacture ID | | 8 | 8 | OTA session not properly initialized | | 9 | 9 | Same image currently running | | 10 | 10 | Time out during OTA download between fragments | | 0 | 0 | No error | | 1 | 1 | Battery low, reflashing not possible |
|
| 2 | HVAC Settings | This configuration setting allows the user to set the HVAC system type the thermostat is controlling. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 3 | 3 | Heat Pump w/ B-Wire | | 1 | 1 | 2 Stage Conventional | | 2 | 2 | Heat Pump w/ O-Wire | | 0 | 0 | 1 Stage Conventional | | 4 | 4 | Heat Pump w/ O-Wire & aux heating | | 5 | 5 | Heat Pump w/ B-Wire & aux heating |
|
| 1 | Display Units | This configuration setting controls the units of which the temperature is displayed in. | 0 | 1 | 0 | 0 | 1 | |
| 11 | Display always on | This configuration setting allows a user to turn the always-on display on or off. This functionality is dependent on a C-Wire connection. *Note: This setting can be modified in battery powered applications but affects are only seen in C-Wire powered applications. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 1 | 1 | Display on in C-Wire powered mode | | 0 | 0 | Display off in C-Wire powered mode |
|