Product Recognition | |
|---|
Certification Number | ZC14-23050253 |
|---|
Name | Yale Assure Keyless Interconnected Touchscreen Lock |
|---|
Short Description | Never worry about carrying around or losing your keys again. Unlock and lock your home with ease from the backlit touchscreen keypad. |
|---|
Long Description | Never worry about carrying around or losing your keys again. Unlock and lock your home with ease from the backlit touchscreen keypad. Create unique pin codes for friends and family and remove codes whenever you need to. This Yale Real Living lock features Z-Wave™ technology and seamlessly integrates into 50+ home automation and security systems. When added to most Z-Wave™ automation systems, lock and unlock your door, create pin codes, view access history and receive notifications from anywhere. The lock is tamper resistant, easy to install and even easier to use! |
|---|
Brand | Yale |
|---|
Product Identifier | YRC642-ZW3 |
|---|
Product Line | Yale |
|---|
OEM Version | HW: 02 FW: 02.38:32.60 |
|---|
Hardware Platform | ZGM130S037HGN2 / ZGM130S037HGN1 |
|---|
Z-Wave Version | 7.16.3 |
|---|
Library Type | END_NODE_ENHANCED_232 |
|---|
Device Type | Lock DT |
|---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_LISTENING |
|---|
Manufacturer ID | 0x0129 |
|---|
Product Type ID | 0x8103 |
|---|
Product ID | 0x52C4 |
|---|
User Icon | 0x0300 |
|---|
Installer Icon | 0x0300 |
|---|
Frequency Plans | US: 916.00MHz, 908.40MHz |
|---|
Categories | Locks |
|---|
Countries / Regions | Canada, Mexico, United States of America |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_BASIC_V2 | Basic V2 | 0x20 | 2 | COMMAND_CLASS_CONFIGURATION_V4 | Configuration V4 | 0x70 | 4 | COMMAND_CLASS_DOOR_LOCK_V4 | Door Lock V4 | 0x62 | 4 | COMMAND_CLASS_DOOR_LOCK_LOGGING | Door Lock Logging | 0x4C | 1 | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V3 | Schedule Entry Lock V3 | 0x4E | 3 | COMMAND_CLASS_USER_CODE_V2 | User Code V2 | 0x63 | 2 | COMMAND_CLASS_APPLICATION_STATUS | Application Status | 0x22 | 1 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information (AGI) V3 | 0x59 | 3 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta Data V5 | 0x7A | 5 | COMMAND_CLASS_INDICATOR_V3 | Indicator V3 | 0x87 | 3 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_TIME_V2 | Time V2 | 0x8A | 2 | COMMAND_CLASS_TIME_PARAMETERS | Time Parameters | 0x8B | 1 | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_SECURITY | Security 0 | 0x98 | 1 | COMMAND_CLASS_SECURITY_2 | Security 2 | 0x9F | 1 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 |
|
|---|
S2 Classes | S2_ACCESS_CONTROL |
|---|
Documents | Category | File |
|---|
Installer_Guide | | Adv_Manual | | Manual_English | |
|
|---|
Features | Feature | Values |
|---|
Door Lock Type | |
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Group Name | Profile |
|---|
1 | 5 | 0 | Lifeline | 0x0001 |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value |
|---|
1 | Volume | Set Volume Level to high (1), low (2), or silent (3). | 1 | 1 | 0 | 0 | 0x01 | 2 | Auto Relock | Set Auto Relock feature to enable or disable. | 1 | 1 | 0 | 0 | 0x00 | 3 | Relock time | Adjust the time your lock will auto relock. | 1 | 1 | 0 | 0 | 0x1E | 4 | Wrong Code Entry Limit | Adjust the limit for wrong code entries allowed by your lock. | 1 | 1 | 0 | 0 | 0x05 | 5 | Language | Set the language to English (1), Spanish (2), or French (3). | 1 | 1 | 0 | 0 | 0x01 | 7 | Shut down time | Adjust the time your lock is shutdown after reaching its wrong code entry limit. | 1 | 1 | 0 | 0 | 0x3C | 8 | Operating mode | Set the Operating Mode to normal mode, vacation mode, privacy mode or passage mode. | 1 | 1 | 0 | 0 | 0x00 | 11 | One Touch Locking | Set One Touch Locking feature to enable or disable. | 1 | 1 | 0 | 0 | 0xFF |
|
|---|
Texts | ID | Description | Value |
|---|
8 | Where to find S2 DSK on product | 1. Install the Yale Smart Module into the slot above the battery compartment
IMPORTANT: The batteries must be removed before removing the Yale Smart Module:
• Remove battery cover
• Remove batteries
• Insert or remove Yale Smart Module
• Reinstall batteries
• Reinstall battery cover
2. Open the Z-Wave system's smart home or alarm app on your smartphone or tablet
3. Follow the in-app instructions for adding a new device
4. On your lock keypad, enter your master entry code followed by the gear icon
5. Press the 7 key followed by the gear icon
6. Press the 1 key followed by the gear icon | 1 | Classic Inclusion | 1. Install the Yale Smart Module into the slot above the battery compartment
IMPORTANT: The batteries must be removed before removing the Yale Smart Module:
• Remove battery cover
• Remove batteries
• Insert or remove Yale Smart Module
• Reinstall batteries
• Reinstall battery cover
2. Open the Z-Wave system's smart home or alarm app on your smartphone or tablet
3. Follow the in-app instructions for adding a new device
4. On your lock keypad, enter your master entry code followed by the gear icon
5. Press the 7 key followed by the gear icon
6. Press the 1 key followed by the gear icon | 2 | Classic Exclusion | 1. On your lock keypad, enter your master entry code followed by the gear icon
2. Press the 7 key followed by the gear icon
3. Press the 3 key followed by the gear icon
4. Open the Z-Wave system's smart home or alarm app and follow the instructions for
removing a device
5. Remove the Yale Smart Module from the slot above the battery compartment
IMPORTANT: The batteries must be removed before removing the Yale Smart Module:
• Remove battery cover
• Remove batteries
• Insert or remove Yale Smart Module
• Reinstall batteries
• Reinstall battery cover
6. If you're adding a new Yale Smart Module, follow the instructions included with it | 4 | Wake-Up Procedure | press any key | 5 | Factory Reset Procedure | When lock is reset to factory defaults all Entry Codes
(including the Master Entry Code*) are deleted and all
programming features are reset to original default
settings (see below).
1. Remove battery cover and batteries.
2. Remove inside lock to access reset button.
3. Reset button (see image at right) is located beside
cable adapter.
4. While pressing reset button reinstall batteries. Hold
reset button a minimum of 3 seconds then release.
5. Replace battery cover.
After reset, Master Entry Code creation is the only
option available and must be performed prior to
any other programming of the lock |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Access Control | Manual lock operation | Access Control | Manual unlock operation | Access Control | RF lock operation | Access Control | RF unlock operation | Access Control | Keypad lock operation | Access Control | Keypad unlock operation | Access Control | Auto lock locked operation | Access Control | Lock state: Lock jammed | Access Control | All user codes deleted | Access Control | Single user code deleted | Access Control | New user code added | Access Control | New user code not added due to duplicate code | Access Control | Keypad state: Keypad temporary disabled | Access Control | New program code entered : unique code for lock configuration | Access Control | Manually enter user access code exceeds code limit | Access Control | Door state: Window/door is open | Access Control | Door state: Window/door is closed | Power Management | Power status: Power has been applied | Power Management | Battery maintenance status: Replace battery soon | Power Management | Battery maintenance status: Replace battery now | Power Management | Battery level status: Battery is fully charged |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Is Flirs | Yes |
|---|
Supports SmartStart | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|