Product Recognition | |
|---|
Certification Number | ZC14-22060109 |
|---|
Name | Z-Wave 700 MOS Dimmer |
|---|
Short Description | ZBD-110 is an inwall dimmer module to dim lighting appliances by Z-WaveTM wireless control. It uses MOS technology to achieve both Trailing-edge dimming for LED lighting and Leading-edge dimming for older lamps. Compact in design, yet certified for safety makes it suitable for installation in crammed electrical box located behind wall switches. |
|---|
Long Description | ZBD-110 is an inwall dimmer module to dim lighting appliances by Z-WaveTM wireless control. It uses MOS technology to achieve both Trailing-edge dimming for LED lighting and Leading-edge dimming for older lamps. Compact in design, yet certified for safety makes it suitable for installation in crammed electrical box located behind wall switches. |
|---|
Brand | NEXA |
|---|
Product Identifier | ZBD-110 |
|---|
Product Line | Z-Wave 700 series |
|---|
OEM Version | HW: 01 FW: 01.01:00.03 |
|---|
Hardware Platform | ZGM130S037HGN2 / ZGM130S037HGN1 |
|---|
Z-Wave Version | 7.16.3 |
|---|
Library Type | END_NODE_ENHANCED_232 |
|---|
Device Type | Multilevel Switch DT |
|---|
Role Type | ROLE_TYPE_SLAVE_ALWAYS_ON |
|---|
Manufacturer ID | 0x0060 |
|---|
Product Type ID | 0x0033 |
|---|
Product ID | 0x0001 |
|---|
User Icon | 0x0600 |
|---|
Installer Icon | 0x0600 |
|---|
Frequency Plans | EU: 869.85MHz, 868.40MHz |
|---|
Categories | All Lighting Devices, On/Off Switches/Devices, Dimming Lighting Devices |
|---|
Countries / Regions | European Union |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_BASIC_V2 | Basic V2 | 0x20 | 2 | COMMAND_CLASS_CONFIGURATION_V4 | Configuration V4 | 0x70 | 4 | COMMAND_CLASS_METER_V5 | Meter V5 | 0x32 | 5 | COMMAND_CLASS_SWITCH_MULTILEVEL_V4 | Multilevel Switch V4 | 0x26 | 4 | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | COMMAND_CLASS_APPLICATION_STATUS | Application Status | 0x22 | 1 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information (AGI) V3 | 0x59 | 3 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta Data V5 | 0x7A | 5 | COMMAND_CLASS_INDICATOR_V3 | Indicator V3 | 0x87 | 3 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_SECURITY | Security 0 | 0x98 | 1 | COMMAND_CLASS_SECURITY_2 | Security 2 | 0x9F | 1 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 |
|
|---|
S2 Classes | S2_AUTHENTICATED, S2_UNAUTHENTICATED |
|---|
Documents | Category | File |
|---|
Manual_English | |
|
|---|
Features | Feature | Values |
|---|
Electric Load Type | Value |
|---|
Incandescent | Dimmable LED | Dimmable ELV (Magnetic) |
| Firmware Updatable | Value |
|---|
Updatable by Consumer by RF |
|
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Group Name | Profile |
|---|
1 | 5 | 0 | Lifeline | 0x0001 | 2 | 5 | 0 | On/Off Control | 0x2001 | 3 | 5 | 0 | Switch Multilevel Start/Stop | 0x2002 |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value |
|---|
1 | Switch Type | Def 0 | 0 | 2 | 0 | 0 | 0x0000 | 2 | Auto-on time | Def 0, second | 0 | 2 | 0 | 0 | 0x0000 | 3 | Auto-off time | Def 0, second | 0 | 2 | 0 | 0 | 0x0000 | 4 | Remember last status | Def 1, save last state | 0 | 2 | 0 | 0 | 0x0001 | 5 | Interval for wattage/kWh auto report | Def 600, second | 0 | 2 | 0 | 0 | 0x0258 | 6 | Report when exceed % change of wattage | Def 25, percent | 0 | 2 | 0 | 0 | 0x0019 | 7 | Maximum dimming value | Def 100" | 0 | 2 | 0 | 0 | 0x0064 | 8 | Minimum dimming value | Def 100 | 0 | 2 | 0 | 0 | 0x000A | 9 | MOS operation mode | Def 2 | 0 | 2 | 0 | 0 | 0x0002 | 10 | Calibration Mode | Def 0 | 0 | 2 | 0 | 0 | 0x0000 | 11 | Auto Calibration | Def 1 | 0 | 2 | 0 | 0 | 0x0001 | 17 | Power auto report threshold | Def 0, 0: disable | 0 | 2 | 0 | 0 | 0x0000 |
|
|---|
Texts | ID | Description | Value |
|---|
8 | Where to find S2 DSK on product | Page 2: Adding to Z-Wave Network
Note: If the Z-Wave Controller utilizes S2 security protocol, you may be asked to enter a 5 digit Device Specific Key (DSK) .This can be found in one of two places:
- on the QR code label on the back of the unit
- on the insert card inside the packaging | 1 | Classic Inclusion | 1. Put the Z-Wave Controller into inclusion mode.
2. Press the link key or external switch three times within 1.5 seconds to put the unit into inclusion mode. | 2 | Classic Exclusion | 1. Put the Z-Wave Controller into exclusion mode.
2. Press the link key or external switch three times within 1.5 seconds to put the unit into exclusion mode. | 5 | Factory Reset Procedure | 1. Press the link key or external switch three times within 1.5 seconds to put the unit into exclusion mode.
2. Within 1 second of step 1, press link key or external switch again and hold until LED is off (about 5 seconds).
3. Node ID is excluded. The device reverts to factory default state and will be in auto-inclusion mode for 4 minutes.
(This procedure should only be used when the network primary controller is inoperable.) |
|
|---|
Supported / Controlled Meter Types | Meter Type | Rate Type |
|---|
Electric meter | Import (consumed) |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Power Management | Power status: Power has been applied | Power Management | Over-load status: Over-load detected | System | HW status: System hardware failure | System | Emergency shutoff status: Emergency shutoff |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Supports SmartStart | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|