10 | Input 1 trigerring | Connect input and output or separate the output from the input for switch 1 | 2 | 1 | 0 | 1 | 1 |
Warning: Undefined variable $field_object in /nas/content/live/zwaprodcatalog/wp-content/themes/hello-elementor-child/single-z-wave-product.php on line 98
From | To | Description |
|---|
1 | 1 | trigger unable (default); trigger the relay and hub notification | 0 | 0 | trigger disable (only notification to hub according to set par 2) |
| |
6 | EP1 Auto Turn-off Timer | Setting auto off timer value for relay one | 2 | 4 | 0 | 65535 | 0 | From | To | Description |
|---|
0 | 65535 | EP1 Auto Turn-off Timer |
| |
1 | Restore state after power failure | Restore state after power failure: always off, always on or follow the status before power failure | 2 | 1 | 0 | 4 | 1 | From | To | Description |
|---|
0 | 0 | All relays automatically turn OFF once power is restored | 1 | 1 | All relays remember the status prior to power outage and turns back to it | 2 | 2 | All relays turned on after power failure | 3 | 3 | R1 recovered, R2 ON | 4 | 4 | R2 recovered, R1 – ON |
| |
7 | EP1 Auto Turn-on Timer | Setting auto on timer value for relay one | 2 | 4 | 0 | 65535 | 0 | From | To | Description |
|---|
0 | 65535 | EP1 Auto Turn-on Timer |
| |
2 | Select switch one's type | Select switch one's type: switch or sensor | 2 | 1 | 0 | 9 | 2 | From | To | Description |
|---|
0 | 0 | momentary switch | 1 | 1 | toggle switch (contact closed -ON, contact opened - OFF) | 2 | 2 | toggle switch (device changes status when switch changes status) | 3 | 3 | garage door mode(toggle switch type for external switch (like in value 1) + built-in 2 second auto-off timer for Z-Wave control (so if user turns the relay on from the Z-Wave hub, it will automatically turn off after 2 seconds) | 4 | 4 | water alarm | 5 | 5 | heat alarm | 6 | 6 | Smoke alarm | 7 | 7 | Door alarm | 8 | 8 | CO alarm | 9 | 9 | CO2 alarm |
| Yes |
3 | Select switch two's type | Select switch two's type: switch or sensor | 2 | 1 | 0 | 9 | 2 | From | To | Description |
|---|
0 | 0 | momentary switch | 1 | 1 | toggle switch (contact closed -ON, contact opened - OFF) | 2 | 2 | toggle switch (device changes status when switch changes status) | 3 | 3 | garage door mode(toggle switch type for external switch (like in value 1) + built-in 2 second auto-off timer for Z-Wave control (so if user turns the relay on from the Z-Wave hub, it will automatically turn off after 2 seconds) | 4 | 4 | water alarm | 5 | 5 | heat alarm | 6 | 6 | Smoke alarm | 7 | 7 | Door alarm | 8 | 8 | CO alarm | 9 | 9 | CO2 alarm |
| Yes |
8 | EP2 Auto Turn-off Timer | Setting auto off timer value for relay two | 2 | 4 | 0 | 65535 | 0 | From | To | Description |
|---|
0 | 65535 | EP2 Auto Turn-off Timer |
| |
11 | Input 2 trigerring | Connect input and output or separate the output from the input for switch 2 | 2 | 1 | 0 | 1 | 1 | From | To | Description |
|---|
0 | 0 | trigger disable (only notification to hub according to set par 2) | 1 | 1 | trigger unable (default); trigger the relay and hub notification |
| |
9 | EP2 Auto Turn-on Timer | Setting auto on timer value for relay two | 2 | 4 | 0 | 65535 | 0 | From | To | Description |
|---|
0 | 65535 | EP2 Auto Turn-on Timer |
| |
5 | LED indicator | Indicator inverse, follow, always on or always off | 2 | 1 | 0 | 3 | 0 | From | To | Description |
|---|
0 | 0 | LED on when relay off, LED off when relay on | 1 | 1 | LED on when relay on, LED off when relay off | 2 | 2 | LED Always OFF | 3 | 3 | LED Always ON |
| |
24 | Sw1,Sw2 setting | DC motor mode: sync R1 and R2 together to prevent them from being activated at the same time | 2 | 1 | 0 | 1 | 0 | From | To | Description |
|---|
0 | 0 | Normal | 1 | 1 | Union (only switch type1 < 4 && switch type2 < 4) IF both switches OFF - only one of them may be turned ON. - turning sw1 ON : delayed 0.5 s, sw2 and R2 turned off first (immediately) - turning sw2 ON - delayed 0.5s , sw1and R1 turned off first ( immediately ) The situation for DC motor control(SW1 control—right, SW2 control-left. -main switch can turn ON and OFF only sw1 |
| |
17 | EP2 Auto Turn-Off Timer Unit | Setting auto off timer unit(minutes, seconds or hours) for relay two | 2 | 1 | 0 | 2 | 0 | From | To | Description |
|---|
2 | 2 | hours | 1 | 1 | seconds | 0 | 0 | minutes |
| |