| 6 | Power Report Percentage Threshold | Choose how you want your Mini Plug to report power consumption, electricity, voltage, and energy usage to your controller and associated devices by percentage rate. The number entered as the value corresponds to the change in percentage the appliance needs to go over for the event to be reported. So if 5% is entered by default, the Mini Plug will report any change in power consumption (W), voltage (V), electricity (A), or energy usage (kWH) over 5% (whether it’s at least 5% more or 5% less compared to previous report). | 0 | 1 | 0 | 0 | 5 | | From | To | Description |
|---|
| 1 | 100 | Percentage of change in power consumption, voltage, electricity, or energy usage to be reported to controller by the Mini Plug |
|
| 7 | On/Off Status Recovery After Power Failure | Choose the recovery state for your Mini Plug if power outage occurs. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 0 | 0 | Mini Plug automatically turns OFF once power is restored (it does not remember the status prior to power outage) | | 1 | 1 | Mini Plug remembers the status prior to power outage and turns back to it |
|
| 8 | Auto Turn-Off Timer | Parameter 8: Use this parameter to enable or disable the auto turn-off timer function. If this feature is enabled, the Mini Plug will automatically turn off after a fixed period of time (set in parameter 9). | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | timer disabled | | 1 | 1 | timer enabled |
|
| 9 | Auto Turn-Off Timer Settings | Use this parameter to set the time after which you want the Mini Plug to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes. | 0 | 2 | 0 | 0 | 150 | | From | To | Description |
|---|
| 1 | 65535 | Number of minutes the Mini Plug will turn off after once the auto turn-off timer is enabled |
|
| 10 | Manual Control | Choose if you want to use the Z-Wave button to turn the Mini Plug on or off manually or if you want to disable this function. If this parameter is set to 0 (disabled), you will only be able to turn the Mini Plug on or off remotely using your Z-Wave gateway controller. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 0 | 0 | manual control disabled | | 1 | 1 | manual control enabled |
|
| 1 | Metering Report | Choose if you want the Mini Plug to send metering reports to the controller. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 0 | 0 | Metering disabled | | 1 | 1 | Metering enabled |
|
| 2 | Metering Report Frequency | Choose how often you want the Mini Plug to send metering reports to the controller. The number entered as the value corresponds to the number of seconds. So if 300 is entered by default, the Mini Plug will report power consumption every 300 seconds (5 minutes). | 0 | 2 | 0 | 0 | 300 | | From | To | Description |
|---|
| 1 | 65536 | Number of seconds metering report is sent to controller |
|
| 5 | LED Notifications | Use this parameter to turn LED notifications on or off. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 0 | 0 | LED disabled | | 1 | 1 | LED enabled |
|