| 42 | Freeze Alarm Operation Mode | Decide if you want to allow the valve actuator to open and close during freeze alarm mode. If the actuator is disabled, it won't react to Z-Wave or manual triggers to open or close until the freeze alarm is cleared. | 3 | 1 | 0 | 1 | 1 | | From | To | Description |
|---|
| 0 | 0 | operation disabled | | 1 | 0 | operation enabled (default) |
|
| 41 | Freeze Recover Value | Set the freeze alarm cancellation trigger value. Default: 36. | 2 | 2 | 0 | 511 | 292 | | From | To | Description |
|---|
| 0 | 511 | degrees |
|
| 43 | Association Group 5 Freeze Trigger | Decide which report is sent to Group 5 when the freeze alarm (set in parameter 40) is triggered. | 3 | 1 | 0 | 2 | 0 | | From | To | Description |
|---|
| 2 | 0 | Basic Set off | | 0 | 0 | reports to Group 5 disabled (default) | | 1 | 0 | Basic Set on |
|
| 44 | Association Group 5 Freeze Cancel | Decide which report is sent to Group 5 when the freeze alarm is cancelled. | 3 | 1 | 0 | 2 | 0 | | From | To | Description |
|---|
| 2 | 0 | Basic Set off | | 1 | 0 | Basic Set on | | 0 | 0 | reports to Group 5 disabled (default) |
|
| 49 | Association Group 3 Water Leak Trigger | Decide which report is sent to Group 3 when a leak alarm is triggered (from the connected leak detection probe).
Values: | 3 | 1 | 0 | 2 | 1 | | From | To | Description |
|---|
| 2 | 0 | Basic Set off | | 1 | 0 | Basic Set on (default) | | 0 | 0 | reports to Group 3 disabled |
|
| 65 | Buzzer | Decide if you'd like to receive sound (beep) feedback when operating the actuator as well as sound alarms for different modes and alarms the actuator goes into when installed. | 3 | 1 | 0 | 1 | 1 | | From | To | Description |
|---|
| 0 | 0 | sound notifications disabled | | 1 | 0 | sound notifications enabled (default) |
|
| 66 | LED Brightness Level | Decide how bright you'd like the LED indicator to be on your actuator. If you set it to value 0, the LED indicator will be disabled. Default: 80. | 2 | 1 | 0 | 99 | 80 | |
| 50 | Association Group 3 Water Leak Cancel | Decide which report is sent to Group 3 when the leak alarm is cleared (water is no longer detected by the connected probe). | 3 | 1 | 0 | 2 | 0 | | From | To | Description |
|---|
| 2 | 0 | Basic Set off | | 1 | 0 | Basic Set on | | 2 | 0 | Basic Set off | | 0 | 0 | reports to Group 3 disabled (default) | | 2 | 0 | Basic Set off |
|
| 51 | Water Leak Detection Valve Control | Decide if you want to allow the valve actuator to open and close during a leak alarm event. If the actuator is disabled, it won't react to Z-Wave or manual triggers to open or close until the leak alarm is cleared. | 3 | 1 | 0 | 1 | 1 | | From | To | Description |
|---|
| 0 | 0 | operation disabled | | 1 | 0 | operation enabled (default) |
|
| 17 | Water Valve Command and Reporting Behavior | Decide which Z-Wave commands and reports you'd like to use to display when the device is open or closed (or to open / close the device). Default value: 1. | 3 | 1 | 0 | 1 | 1 | | From | To | Description |
|---|
| 0 | 0 | reports on when the valve is open (opens the valve when an "on" report is sent from the hub), reports off when the valve is closed (closes the valve when an "off" report is sent from the hub) | | 1 | 0 | reports off when the valve is open (opens the valve when an "off" report is sent from the hub), reports on when the valve is closed (closes the valve when an "on" report is sent from the hub) |
|
| 67 | Z-Wave Button Lock Protection | Enable Z-Wave button lock protection if you'd like to prevent the Z-Wave button from being locked accidentally. | 3 | 1 | 0 | 1 | 0 | | From | To | Description |
|---|
| 0 | 0 | Z-Wave button lock disabled (default) | | 1 | 0 | Z-Wave button lock enabled |
|