| Product Recognition | |
|---|
| Certification Number | ZC10-16125347 |
|---|
| Name | Wall Scene Controller |
|---|
| Short Description | The Wall Scene Controller is a Z-Wave device that can both control other Z-Wave devices and activate scenes. |
|---|
| Long Description | The Wall Scene Controller is a Z-Wave device that can both control other Z-Wave devices and activate scenes. Although it is controlling other devices, the Wall Controller cannot act as Z-Wave network controller (primary or secondary) and will always need a Z-Wave network controller to be included into a Z-Wave network. The device can be used in different modes that are selected by configuration parameters:
Control of groups of other Z-Wave devices using 'ON', 'OFF' and Dim commands. Activation of predefined scenes in Gateways or other Z-Wave devices. This device support secure communication when included by a controller that also supports secure communication. |
|---|
| Brand | Popp |
|---|
| Product Identifier | POPE009303 |
|---|
| OEM Version | HW: 1 FW: 1.01 |
|---|
| Hardware Platform | ZM5202 |
|---|
| Z-Wave Version | 6.51.01 |
|---|
| Library Type | SLAVE_ENHANCED_232 |
|---|
| Device Type | Wall Controller |
|---|
| Role Type | ROLE_TYPE_SLAVE_PORTABLE |
|---|
| Manufacturer ID | 0x0154 |
|---|
| Product Type ID | 0x0100 |
|---|
| Product ID | 0x0101 |
|---|
| User Icon | 0x0b00 |
|---|
| Installer Icon | 0x0b00 |
|---|
| Frequency Plans | EU: 869.85MHz, 868.40MHz |
|---|
| Categories | All Controllers, Handheld Controller, Lighting Accessories |
|---|
| Countries / Regions | European Union |
|---|
| Supported Command Classes | | Identifier | Name | Key | Version |
|---|
| COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | | COMMAND_CLASS_CENTRAL_SCENE | Central Scene | 0x5B | 1 | | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | | COMMAND_CLASS_MANUFACTURER_SPECIFIC | Manufacturer Specific | 0x72 | 1 | | COMMAND_CLASS_SCENE_CONTROLLER_CONF | Scene Controller Conf | 0x2D | 1 | | COMMAND_CLASS_MULTI_CMD | Multi-Command | 0x8F | 1 |
|
|---|
| Controlled Command Classes | | Identifier | Name | Key | Version |
|---|
| COMMAND_CLASS_SWITCH_MULTILEVEL | Switch Multilevel | 0x26 | 1 | | COMMAND_CLASS_DOOR_LOCK | Door Lock | 0x62 | 1 | | COMMAND_CLASS_BASIC | Basic | 0x20 | 1 | | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | | COMMAND_CLASS_CENTRAL_SCENE | Central Scene | 0x5B | 1 | | COMMAND_CLASS_MULTI_CHANNEL_V3 | Multi-Channel V3 | 0x60 | 3 | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2 | Multi Channel Association V2 | 0x8E | 2 | | COMMAND_CLASS_MULTI_CMD | Multi-Command | 0x8F | 1 |
|
|---|
| Documents | |
|---|
| Features | | Feature | Values |
|---|
| Battery Quantity | | | Battery Type | | | Color | | | Z-Wave Scene Type | | Value |
|---|
| Scene & Central Scene |
|
|
|---|
| Association Groups | | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
| 1 | 10 | 0 | Z-Wave Plus Lifeline | | 2 | 10 | 0 | Control Group A, controlled by button 1 or single clicks of buttons 1 and 3 | | 3 | 10 | 0 | Control Group B, controlled by button 2 or single clicks of buttons 2 and 4 | | 4 | 10 | 0 | Control Group C, controlled by button 3 or double clicks of buttons 1 and 3 | | 5 | 10 | 0 | Control Group D, controlled by button 4 or double clicks of buttons 2 and 4 |
|
|---|
| Configuration Parameters | | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
| 1 | Button 1 and 3 pair mode | In separate mode button 1 works with group A, button 3 with groups C. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button 1/3 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group A, double click with group C. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 0 | 0 | seperately | | 1 | 1 | In pair without double clicks | | 2 | 2 | In pair with double clicks |
| | 2 | Button 2 and 4 pair mode | In separate mode button 2 works with control group B, button 4 with control group D. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button B/D are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group B, double click with group D. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 0 | 0 | seperately | | 1 | 1 | In pair without double clicks | | 2 | 2 | In pair with double clicks |
| | 11 | Command to Control Group A | This parameter defines the command to be sent to devices of control group A when the related button is pressed | 0 | 1 | 0 | 0 | 8 | | From | To | Description |
|---|
| 0 | 0 | Disabled | | 1 | 1 | Switch On/Off and Dim (send Basic Set and Switch Multilevel) | | 2 | 2 | Switch On/Off only (send Basic Set) | | 3 | 3 | Switch All | | 4 | 4 | Send Scenes | | 5 | 5 | Send Preconfigured Scenes | | 7 | 7 | Control DoorLock | | 8 | 8 | Central Scene to Gateway |
| | 25 | Blocks wakeup even when wakeup interval is set | | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 0 | 0 | Wakeup is blocked | | 1 | 1 | Wakeup is not blocked |
|
|
|---|
| Texts | | ID | Description | Value |
|---|
| 5 | Factory Reset | Use this procedure only if the primary controller is missing or otherwise inoperable.
(1) Turn the device into Management Mode by keeping all four buttons pushed for 5 seconds, (2) click on Button 3, (3) keep button 4 pushed for 4 seconds. | | 4 | Device Wake-Up | (1) Turn the device into Management Mode by keeping all four buttons pushed for 5 seconds, (2) click on Button 2. | | 24 | Controller Exclusion | Re-Inclusion and Exclusion are performed by pushing button 1 in management mode. Pushing all four buttons for 5 sec. turns the device into management mode (indicated by blinking green LED). | | 23 | Controller Inclusion | Place your primary controller in inclusion mode by following the manufacturer's instructions, then activate inclusion on the wall controller by pressing any one of the four buttons for one second. Inclusion mode is indicated by the red/green blinking of the LEDs until the timeout occurs after 10 seconds. |
|
|---|
| Supports NWI | Yes |
|---|
| Supports Explorer Frames | Yes |
|---|