Product Recognition | |
|---|
Certification Number | ZC12-20030036 |
|---|
Name | Motion Sensor Pet Immunity Z-Wave 700 |
|---|
Short Description | MOTION SENSOR PET IMMUNITY Z-WAVE 700 |
|---|
Long Description | The Motion Sensor lets you know when movement is detected in a certain area and can trigger different actions in response to that movement(or lack of movement). It supports the pet immunity up to 80 lbs. |
|---|
Brand | LEEDARSON |
|---|
Product Identifier | 7CA-SS-VE-C0 |
|---|
Product Line | Security |
|---|
OEM Version | HW: 1 FW: 1.00 |
|---|
Hardware Platform | ZGM130 |
|---|
Z-Wave Version | 7.12.2 |
|---|
Library Type | SLAVE_ENHANCED_232 |
|---|
Device Type | Notification Sensor |
|---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_REPORTING |
|---|
Manufacturer ID | 0x0300 |
|---|
Product Type ID | 0x0300 |
|---|
Product ID | 0x0042 |
|---|
User Icon | 0x0C07 |
|---|
Installer Icon | 0x0C07 |
|---|
Frequency Plans | EU: 869.85MHz, 868.40MHz |
|---|
Categories | Sensors |
|---|
Countries / Regions | European Union |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_CONFIGURATION_V4 | Configuration V4 | 0x70 | 4 | COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | Sensor Multilevel V5 | 0x31 | 5 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V4 | Multi-Channel Association V4 | | 0 | COMMAND_CLASS_INDICATOR_V3 | Indicator V3 | 0x87 | 3 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta-Data V5 | 0x7A | 5 | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information V3 | 0x59 | 3 | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | COMMAND_CLASS_BASIC_V2 | Basic V2 | 0x20 | 2 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 |
|
|---|
S2 Classes | S2_UNAUTHENTICATED, S2_AUTHENTICATED |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product Manual in English | |
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Group Name | Profile | Description |
|---|
2 | 5 | 0 | On/Off control | 0x7107 | this is the on/off control group; the command listed below will be sent to the nodes in this group in response to on/off control event. | 1 | 5 | 0 | Lifeline | 0x0001 | This is the Lifeline group; the commands listed below will be sent to the node(s) in this group in response to lifeline notification events. |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
17 | PirPetImmunity | Enable/disable pet immunity mode. This feature is lens dependent and detection range may be reduced when Pet Immunity is enabled. 0 = Disable the pet immunity mode 1 = Enable the pet immunity mode | 2 | 1 | 0 | 1 | 0 | From | To | Description |
|---|
0 | 1 | 0 = Disable the pet immunity mode 1 = Enable the pet immunity mode |
| 10 | LowBatPrecent | Low battery power level of alarm threshold values: the value range are 5~50 for percentage, the battery low power level can setting 5%~50%. | 2 | 1 | 5 | 50 | 10 | From | To | Description |
|---|
5 | 50 | 5: This value 5 here means that device will report a low batter alarm to association group 1 when the batter level is less than 5%. the value 50 means 5: This value 5 here means that device will report a low batter alarm to association group 1 when the batter level is more than 50%. |
|
|
|---|
Texts | ID | Description | Value |
|---|
8 | Where to find S2 DSK on product | on the saide of the product | 2 | Classic Exclusion | Remove Motion Sensor from a Z-Wave network:
1. Power on your Motion Sensor, and let the Z-Wave primary controller into remove mode.
2. Press the button on the Motion Sensor, the LED will be turn on for 60seconds.
3. If Motion Sensor has been successfully removed from your Z-Wave network, the LED will be fast blink 2 seconds. If failed, LED will be turn off forever, and please repeat the steps in above. | 4 | Wake-Up Procedure | In the network: Send Wake up notification, and LED will fast blink when sending data, send over then the LED turn off. | 5 | Factory Reset Procedure | Reset Motion Sensor to factory default.
NOTE:
1. Triggering this action, in 5 seconds LED will be fast blink. The LED will be turn on within 2 second until hold time is equal to 5 seconds. Motion Sensor will send “Device_Reset_Locally” to the main controller and exclude from the Z-Wave network when the button is released, this procedure will reset the sensor to factory default.
2. Please use this procedure only when the network primary controller is missing or otherwise inoperable.
3. When not in the network, ignore this operation. | 17 | Dynamic Capabilities | NA | 1 | Classic Inclusion | Add the Motion Sensor into the Z-Wave network:
1. Power on your Motion Sensor, and let your Z-Wave controller into add/inclusion mode.
2. Implement the button action, the Motion Sensor will send out a node info security CC in command class list (Security inclusion), the LED will be fast blink for 60 seconds.
3. If the inclusion is successful, the LED will be turn on within 2 seconds. If failed, LED will be turn off forever, and please repeat the steps in above. |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Home Security | (Refer to parameters): State idle | Home Security | Cover status: Tampering, product cover removed | Home Security | Motion sensor status: Motion detection | Power Management | (Refer to parameters): State idle | Power Management | Battery maintenance status: Replace battery soon | Power Management | Battery maintenance status: Replace battery now | Light sensor | (Refer to parameters): State idle | Light sensor | Light detection status: Light detected |
|
|---|
Supported Multilevel Sensors | Multilevel Sensor Type |
|---|
Illuminance |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Supports SmartStart | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|