| Product Recognition | |
|---|
| Certification Number | ZC10-17025438 |
|---|
| Name | Smart Plug |
|---|
| Short Description | Smart- Plug plugs in between any appliance and the AC outlet. |
|---|
| Long Description | Smart- Plug plugs in between any appliance and the AC outlet.
It measures its power consumption & sends that information
to your smartphone . It can also control power source
connected with appliance manually and remotely using
smartphone. |
|---|
| Brand | LG Uplus |
|---|
| Product Identifier | SPES - 02A |
|---|
| OEM Version | HW: 1 FW: 39.128 |
|---|
| Hardware Platform | ZM5101 |
|---|
| Z-Wave Version | 6.61.00 |
|---|
| Library Type | SLAVE_ENHANCED_232 |
|---|
| Device Type | On/Off Power Switch |
|---|
| Role Type | ROLE_TYPE_SLAVE_ALWAYS_ON |
|---|
| Manufacturer ID | 0x0247 |
|---|
| Product Type ID | 0x0042 |
|---|
| Product ID | 0x0002 |
|---|
| User Icon | 0x0700 |
|---|
| Installer Icon | 0x0700 |
|---|
| Frequency Plans | KR: 920.90MHz, 921.70MHz, 923.10MHz |
|---|
| Categories | Energy Meters, All Lighting Devices, On/Off Switches/Devices |
|---|
| Countries / Regions | Republic of Korea |
|---|
| Supported Command Classes | | Identifier | Name | Key | Version |
|---|
| COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | | COMMAND_CLASS_TIME_PARAMETERS | Time Parameters | 0x8B | 1 | | COMMAND_CLASS_SWITCH_BINARY | Switch Binary | 0x25 | 1 | | COMMAND_CLASS_BASIC | Basic | 0x20 | 1 | | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | | COMMAND_CLASS_METER_V3 | Meter V3 | 0x32 | 3 | | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 | Firmware Update Meta-Data V2 | 0x7A | 2 | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | | COMMAND_CLASS_NOTIFICATION_V4 | Notification V4 | 0x71 | 4 |
|
|---|
| Documents | |
|---|
| Features | | Feature | Values |
|---|
| Firmware Updatable | | Value |
|---|
| Updatable by Professional/Technician |
| | Switch Load Capacity Watts | | | Supported Meter Type | | | Switch Type | |
|
|---|
| Association Groups | | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
| 1 | 5 | 0 | Z-Wave Plus Lifeline The following Z-Wave signals may be sent to the nodes in this group: NOTIFICATION_REPORT, METER_REPORT, and CONFIGURATION_REPORT |
|
|---|
| Configuration Parameters | | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
| 1 | standby power | First 3 Bytes : Standby Power Setting Value Last 1 Byte : Standby Power Enable/Disable If the value is set by 1000, standby power equals 10.00w (0x0003E8) and standby power enable is 1. total 0x0003E801 | 0 | 4 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | standby power disable | | 257 | 524033 | standby power enable with 0.01 to 20.47 W Standby |
| | 3 | power accumulation mode | Power Accumulation Start/Stop | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 0 | 0 | Power Accumulation Stop | | 1 | 1 | Power Accumulation Start |
| | 4 | device usage | Connected Device Use / Not Use | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 1 | 1 | Connected Device Use | | 0 | 0 | Connected Device Not Use |
| | 5 | meter transmit interval | Periodic Measurement Value Transmission Interval Minimum time interval : 10minutes Value : 1 (10minutes * 1) = 10minutes interval Value : 2 (10minutes * 2) = 20minutes interval …….. Value : 127(10min * 72) = 720 minutes interval =>MAX | 0 | 1 | 0 | 0 | 6 | | From | To | Description |
|---|
| 1 | 72 | 10min to 720 min |
| | 2 | meter transmit | Periodic Measurement Value Transmission Enable/Disable | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 1 | 1 | Periodic Measurement Value Transmission Enable | | 0 | 0 | Periodic Measurement Value Transmission Disable |
|
|
|---|
| Texts | | ID | Description | Value |
|---|
| 2 | Exclusion | 1. Put your Z-Wave controller into exclusion mode
2. Plug the SmatPlug into the power outlet.
3. Press and hold on/off button about 5 seconds.
4. Orange LED will be flashing about 2 seconds, then exclusion process will be start.
5. Wait until exclusion will be done. | | 1 | Inclusion | 1. Put your Z-Wave controller into inclusion mode.
2. Plug the SmatPlug into the power outlet.
3. Press and hold on/off button about 5 seconds.
4. Orange LED will be flashing about 2 seconds, then inclusion process will be start.
5. Wait until inclusion will be done. | | 5 | Factory Reset | Please use this procedure only when the network primary controller is missing or otherwise inoperable.
1. Plug the SmatPlug into the power outlet.
2. Press and hold on/off button about 10 seconds.
3. Orange LED will be flashing about 2 seconds, then factory reset process will be start. |
|
|---|
| Supported / Controlled Meter Types | | Meter Type | Rate Type | Description |
|---|
| Electric meter | Import | Electric Meter Consumption |
|
|---|
| Supports NWI | Yes |
|---|
| Supports Explorer Frames | Yes |
|---|